Datasheet
Table Of Contents

|2
Front Panel Description
1. AC ON/OFF Switch
2. Air Intake allows zero stacking for maximum system flexibility and power density.
3. Reliable encoder controls Output Voltage and sets Address.
4. Volt Display shows Output V P
oltage and directly displays OV L, UV and Address settings.
5. Reliable encoder controls Output Current, sets baudrate, and Advanced Parallel Mode
6. Current Display shows Output Current and displays baudrate.
7. Function/Status LEDs:
8. Pushbuttons allow flexible user configuration
•
Coarse and fine Adjustment of Output Voltage/Current and Advanced Parallel Master or Slave select.
•
Preview settings and set Voltage/Current with Output OFF
•
Set OVP and UVL Limits
•
Set Current Foldback
•
Local/Remote Mode and select Address and Baudrate
•
Output ON/OFF and Auto-Start/Safe-Start Mode
•
Alarm
•
Fine Control
•
Preview Settings
•
Foldback Mode
•
Remote Mode
•
Output On
1. Remote/Local Output Voltage Sense Connections.
2. DIP Switches select 0-5V or 0-10V Programming and other functions.
3. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor and other functions.
4. RS-485 OUT to other Genesys™ Power Supplies.
5. RS-232/RS-485 IN Remote Serial Programming.
6. Output Connections: R
ugged busbars for up to 60V Output; Terminal block for Outputs >60V.
7. Exit air assures reliable operation when zero stacked.
8. Wide-Range Input 85-265VAC continuous, 47/63Hz with Active Power Factor Correction (0.99 typical)
AC Input Connector: 750W (IEC320), 1500W (screw terminal-shown).
9. Optional Interface Position for IEEE488.2 SCPI (shown), Isolated Analog Interface,
LAN Interface or USB Interface.
LAN Interface complies with Class C Specification
Rear Panel Description
2 4
7
1
9
3 6 5
8
2 31 4 6 7 85