2.9.8 THE SUMMARY REGISTERS
2.9.8.1 INSTRUMENT SUMMARY 1/2/3
The INSTRUMENT SUMMARY EVENT REGISTER, ISUM1 through ISUM3 (see Figure 6), will
record the address of the supply causing an SRQ. These are ‘EVENT’ registers and the bits will
remain set until read by the STAT:QUES:INST:ISUMn command. They are always enabled.