Information


2.5 OPERATING CONDITION COMMANDS
2.5.1 SYSTEM ERROR ENABLE COMMAND
Clears the Error Queue and enables all error messages to be placed in the System Error Queue.
Refer to Section 3 : SYSTEM:ERROR MESSAGES for details
Syntax:
SYSTem:ERRor:ENABle
Action:
Direct the interface to save error messages.
Example:
SYSTEM:ERROR:ENABLE
2.5.2 READ SYSTEM ERROR COMMAND
The oldest error message is removed from the Error Queue and placed in the Output Queue. If
the Error Queue was empty, a 0 is placed in the Output Queue.
Syntax:
SYSTem:ERRor?
Example:
SYSTEM:ERROR?
Returned Message Example:
-222, “Data out of range”
2.5.3 READ SUPPLY OUTPUT MODE COMMAND
Read if the Power Supply is in the Constant Voltage, Constant Current or Output Off Mode.
The interface will return a CV if the supply is in Constant Voltage Mode, a CC if the supply is in
Constant Current Mode or an OFF if the supply output is off.
Syntax
SOURce:MODe?:
Example:
SOURCE:MODE?:
Returns:
CV
CC or
OFF
2.5.4 SET POWER SUPPLY POWER-UP MODE COMMAND
Set the Power Supply for Auto-Restart or Safe-Start operation upon power up.
Syntax:
OUTPut:PON<SP><value>
where value = 0 or OFF for Safe-Start or value = 1 or ON for Auto-Restart
Examples:
OUTPUT:PON 0,