Information
2.4.1.2 READ THE OVER VOLTAGE PROTECTION LEVEL COMMAND
Read the over voltage protection level of the Power Supply.
Syntax:
[SOURce]:VOLTage:PROTection:LEVel?
Alternate Format
:VOLTAGE:PROTECTION:LEVEL?
Example:
SOURCE:VOLTAGE:PROTECTION:LEVEL?
2.4.1.3 READ OVER VOLTAGE TRIPPED STATE COMMAND
Read if the Power Supply over voltage has tripped.
Syntax:
[SOURce]:VOLTage:PROTection:TRIPped?
Alternate Format:
:VOLTAGE:PROTECTION:TRIPPED?
Example:
SOURCE:VOLTAGE:PROTECTION:TRIPPED?
Read the response number. The normal response is “0” (zero). If a “1” (one) is returned,
an over voltage has occurred and the output is shut down.
2.4.1.4 SET THE UNDER VOLTAGE PROTECTION LEVEL COMMAND
Set the under voltage protection level of the Power Supply.
Syntax:
[SOURce]:VOLTage:LIMit:LOW<SP><value>
Alternate Format:
:VOLTAGE:LIMIT:LOW<SP><value>
Example:
SOURCE:VOLTAGE:LIMIT:LOW 25.00
2.4.1.5 READ THE UNDER VOLTAGE PROTECTION LEVEL COMMAND
Read the under voltage protection level of the Power Supply.
Syntax:
[SOURce]:VOLTage:LIMit:LOW?
Alternate Format
:VOLTAGE:LIMIT:LOW?
Example:
SOURCE:VOLTAGE:LIMIT:LOW?