Information

Alternate Format:
SOURCE:VOLTAGE<SP><value>
:VOLTAGE:AMPLITUDE<SP><value>
:VOLTAGE<SP><value>
Examples:
SOURCE:VOLTAGE:AMPLITUDE 15.77
:VOLTAGE 3.25
2.2.2 READ PROGRAMMED VOLTAGE COMMAND
To read what voltage the supply was programmed to, regardless of the actual voltage,
send the following command and read the response message.
[SOURce]:VOLTage[:AMPLitude]?
Alternate Format:
SOURCE:VOLTAGE?
:VOLTAGE:AMPLITUDE?
:VOLTAGE?
Examples:
SOURCE:VOLTAGE:AMPLITUDE?
:VOLTAGE?
2.2.3 MEASURE VOLTAGE COMMAND
The output voltage can be measured by sending the command:
MEASure:VOLTage?
When the controller does the next IEEE Read, the interface will send the measured
voltage to it.
Example:
MEASURE:VOLTAGE?
2.2.4 PROGRAM OUTPUT CURRENT COMMAND
The output current is programmed by sending the command:
[SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude]<SP><value>
where < value > is any valid current with or without a decimal place.
Alternate Formats:
SOURCE:CURRENT<SP><value>
:CURRENT:AMPLITUDE<SP><value>
:CURRENT<SP><value>
Examples:
SOURCE:CURRENT:AMPLITUDE 15.77
:CURRENT 3.25
2.2.5 READ PROGRAMMED CURRENT COMMAND
To read what current the supply was programmed to, regardless of the actual current, send the
following command and read the response message.
[SOURce]:CURRent[:AMPLitude]?
Alternate Format:
SOURCE:CURRENT?
:CURRENT:AMPLITUDE?
:CURRENT?
Examples:
SOURCE:CURRENT:AMPLITUDE?
:CURRENT?