Information

1.8 CONFIGURING THE SUPPLIES
1RFRQ¿JXUDWLRQLVUHTXLUHGIRUWKH0DVWHU6XSSO\7KH,(((,QWHUIDFHZLOODGDSWWKHDG-
dress of the Master Supply as its IEEE address.
Slave supplies must be given a unique address that is different than the address of the
Master supply. No two supplies may be given the same address. All Slave supplies must
be set for RS485 operation at 19,200 Baud transmission rate.
1.9 THE INTERFACE INPUT BUFFER
The Interface contains a 210 byte input buffer to save commands as they are received from
WKH,(((EXV7KHEXIIHULVGLYLGHGLQWRIRXUWHHQE\WH¿HOGV7KXVWKHFRPPDQG
6285&(92/7$*($03/,78'(ZLOOFRQVXPH¿HOGV
and the command:
92/7$*(ZLOOFRQVXPH¿HOGV
The user may enter more than 1 concatenated command, separated by semicolons, to be
executed. The interface will process all commands before returning any data/status to the
IEEE bus or accepting any new commands to execute. Messages returned to the user will
be the result of the last command executed.
If a command error exists, or the Power Supply reports an error, all subsequent commands
in the buffer will be terminated and the status returned to the user.
,IWKHXVHUHQWHUVPRUHWKDW¿HOGVDQHUURUZLOOEHJHQHUDWHG$OVRLIWKHXVHUHQWHUVPRUH
WKDQE\WHVLQDQ\¿HOGDQHUURUZLOOEHJHQHUDWHG
1.10 GETTING STARTED WITH THE SOFTWARE
A computer can use a variety of controllers, programs, and programming languages for the
IEEE bus. Here is an example showing a minimal program to set the voltage, set the cur-
rent and measure the voltage from a power supply.
1.10.1 EXAMPLE SESSION USING THE ‘IBIC’ CONSOLE
$SRSXODUFRQVROHSURJUDPLV1DWLRQDO,QVWUXPHQWV³:LQ,QWHUDFWLYH&RQWURO´¿OHLELF
exe). As the operator types each command on the computer, at the colon prompt, it is im-
mediately sent to the power supply. This example works only for computers with National
Instruments and compatible IEEE controller cards.
Win32 Interactive Control
Copyright 1996 National Instruments Corporation
All rights reserved.
Type ‘help’ for help or ‘q’ to quit.
: ibdev Controller address
enter board index: 0 Supply Address
enter primary address: 6
enter secondary address: 0
enter timeout: 12