Manual

Page 14 of 16 DSP30 Series, 23416 issue 02, April 2013
Product HANDBOOK
DSP30
xx
Input Parameters:
Description Operation
Nominal input voltage 115/230 VAC(Auto select)
Input frequency range 47 – 63Hz
Maximum inrush current 50A
Output Parameters:
Output Watts Vout (V) Adjustment
range (V)
Output
current (A)
5 5 - 5.5 3
12 11.4 -14.5 2.1
15 13.5 - 16.5 2
30W
24 22.5 – 28.5 1.3
Adjusting output voltage beyond the stated range may cause overvoltage protection (OVP) to operate,
whereby the output will latch off. To reset for normal operation simply adjust the potentiometer to reduce the
output voltage to within its range and cycle the input off then on.
All outputs are SELV except under the following circumstance: Outputs connected in series are non-SELV if
the total output voltage exceeds 60Vdc
If the total voltage of outputs connected in series exceed the 60Vdc SELV limit then all outputs must be
considered non-SELV.
Non-SELV outputs are hazardous and must not be made user accessible. Consideration must be given to
service engineers making inadvertent contact with the output terminals in the end equipment.
All outputs have functional spacing to earth, and due consideration must be given to this in the end product
design.
Cooling for unit
The unit must be mounted on a DIN rail with the output connection uppermost (toward the top of the
equipment/installation) as below.