Datasheet

DRB120-480 Series
,QGXVWULDO 7HVW
DRB120-480 Series
1
www.emea.tdk-lambda.com/drb
120W - 480W Single Output
DIN Rail Mount Power Supplies
Features Benets
•HighEfciency •SavesEnergy&Cost
•NarrowWidth •MoreSpaceinControlEquipment
•CurveB,Conducted&RadiatedEMI •EasierSystemIntegration
•Upto7YeareCap-Life •ProlongedLifetimeExpectation
Notes: (1)Deratelinearlyto92.5%loadfrom100to90VAC(2)EN61000-3-2ClassA(3)Cycleinputvoltagetoreset(4)Seeinstallationmanual
Specication
Model DRB120-24-1 DRB240-24-1 DRB480-24-1
InputVoltageRange VAC 85-264(withstands300VACfor5s) 90-264
(1)
InputFrequency Hz 47-63
InrushCurrent(ColdStart) A 55A(Typicalat230VAC) <40A(at264VAC)
PowerFactor(115/230VAC)
(2)
- 0.98/0.92 0.98/0.96
InputCurrent(115/230VAC) A 1.2/0.7 2.4/1.4 5/2.5
LeakageCurrent264VAC63Hz mA <1 <1.7
LineRegulation % <0.1
LoadRegulation % <1
RippleandNoise % <1
TemperatureCoefcient %/°C <±0.02
OvercurrentProtection A >6.06 >12.12 21-29
OvervoltageProtection
(3)
V 30-35 30-35 30V±2%
OvertemperatureProtection - Yes
HoldUpTime ms 20 20 >16
No-loadPowerConsumption W <1 <1.5 <5
Efciency(120/230VAC) % SeeModelSelector
Averageefciency(230VAC) % >87
LEDIndicator - GreenLED=DCisOK
DCOKSignal - Optocoupler;ONwhenVout>80%ofnominaloutput.50V,5mAmaximum(20mAforDRB480)
OperatingTemperature °C
DRB120/240:-25°Cto+70°C.Startupat-40°C.(Deratelinearlyto50%loadfrom55°Cto70°C)
DRB480:-20°Cto+70°C.Startupat-40°C.(Deratelinearlyto62.5%loadfrom50°Cto70°C)
StorageTemperature °C -40°Cto+85°C
Humidity(noncondensing) %RH 5-95%RH(Operatingandstorage)
Paralleloperation - No
Seriesoperation
(4)
- Yes
Cooling - Convection
WithstandVoltage(for1minute) VAC InputtoOutput3kVAC,InputtoGND1.5kVAC,OutputtoGND500VAC
IsolationResistance MΩ >100MΩat25°C,70%RH&500VDC
Vibration(Nonoperating) - 120/240W:2G,10to55Hz,480W:2G,IEC60068-2-6,10to500Hz
Shock - 120/240W:20G,IEC60068-2-27,half-sine,22ms,3xeachaxisonDINrail,480W:5G
Safetyagencycertications -
UL508,IEC/EN/UL/CSA60950-1,CEMark(LVD,EMC,RoHS2)
Inaddition,fortheDRB120&240:120/240W:EN/UL/CSA62368-1,IEC/EN62477-1OVCIII(CBReport)
Conducted&radiatedEMI - EN55011-B,EN55032-B,CISPR11-B,CISPR22-B,EN61204-3ClassA
Immunity - EN61000-4-2(lvl3),-3(lvl3),-4(lvl3),-5(lvl3),-6(lvl3),-8(lvl4),-11
Linedips - SEMI-F47(200VACinput)
Weight(typ) g 500 750 1000
Size(WxHxD) mm 35x124x125 41x124x125 84x124x125
Casematerial - Metal
Warranty yrs 3

Summary of content (4 pages)