User manual
Page 17 of 18 DPX Series, 17185 issue 02, April 2013
Product HANDBOOK
DPX Series
Mechanical Drawings:
Connection via screw terminals, use 14 – 18AWG wire
Terminal Function
Single O/P Dual O/P Triple O/P
1 (Remote On/Off)
2 Negative Input
3 Negative Input
4 Positive Input
5 No Connection No Connection + Auxiliary
6 - Output - Output (Aux) Common (0V)
7 + Output Common (0V) - Auxiliary
8 No Connection + Output
(Main)
+ Output
(Main)
TDK-Lambda UK Ltd
Kingsley Avenue, Ilfracombe
Devon, EX34 8ES
Telephone - Sales and Service +44 (0)1271 856666
Head Office and Works +44 (0)1271 856600
Facsimile +44 (0)1271 864894
WEBSITE: