User manual

Page 13 of 18 DPX Series, 17185 issue 02, April 2013
Product HANDBOOK
DPX Series
General Safety Instructions:
A suitable mechanical and fire enclosure must be provided by the end use equipment for mechanical and fire
hazard protection.
Environmental Specifications:
Description Operation Storage
Use Indoor -
Temperature See product data below See product data below
Humidity 5 to 95% RH, non-condensing 5 to 95% RH, non-
condensing
Pressure 70kPa - 106kPa 54kPa - 106kPa
Shock MIL-STD-810F
Vibration MIL-STD-810F
Material Group IIIb
Pollution Degree 2
Overvoltage Category II
Class I
Product data:
Product Operation temperature without derating Operation temperature with derating *
DPX15W Series -40°C to +85°C +85°C to +95°C
DPX20 -40°C to +76°C +76°C to +94°C
DPX20W Series -40°C to +78°C +78°C to +91°C
DPX30 -40°C to +70°C +70°C to +94°C
DPX30W Series -40°C to +67°C +67°C to +90°C
DPX40 -40°C to +69°C +69°C to +90°C
DPX40W Series -40°C to +66°C +66°C to +87°C
DPX60 -40°C to +60°C +60°C to +85°C
* With derating (see product datasheet for derating curves).
Storage temperature all DPX: -4C to +105°C
Isolation voltage
Dielectric Strength testing is carried out as follows:
Input to output: 1600Vdc
Input (Output) to chassis: 1600Vdc
Safety Approvals:
CE marking when applied to any DPX product, indicates compliance with the Low Voltage Directive
(2006/95/EC) in that it complies with EN60950-1: 2
nd
Edition
Fusing: The products are internally fused and protected against reverse input polarity (see input parameters
table below)
Symbols:
DC