Datasheet

CUS350M Series
2
Notes: (5)115/230VACinput.Convectionandforcedairratings
Model Selector
Adjust Maximum Maximum Forced Maximum Ripple Efciency
Range Current(A) Power(W) Air Power(W) Noise (typical)
Model Voltage (V) Convection Convection Forced Air (mV) %
(5)
CUS350M-12/F 12V 11.4-12.6 29.0 348.0 34.5 414.0 120 91/93
CUS350M-18/F 18V 17.1-18.9 19.4 349.2 23.0 414.0 180 91/94
CUS350M-24/F 24V 22.8-25.2 14.7 352.8 17.5 420.0 240 91/94
CUS350M-36/F 36V 34.2-37.8 9.7 349.2 11.5 414.0 360 91/93
CUS350M-48/F 48V 45.6-50.4 7.3 350.4 8.7 417.6 480 91/94
Options (available on request)
Sufx“/F FanSupply&PowerGoodSignal Default model in EMEA
Outline Drawing CUS350M Series