Specication
Model CUS350M/F
ACInputVoltage VAC 85-265VAC(1)
InputFrequency Hz 47-63Hz
DCInputVoltage VDC 120-370VDC(Nosafetycertication)
InrushCurrent(coldstart) A 20Aat115VAC,40Aat230VAC
PowerFactor - MeetsEN61000-3-2(TypicalPF0.99/0.95)(2)
InputCurrent(115/230VAC) A 4/2A(350Woutput)
Off-loadPowerConsumption(3) W <0.5Wat230VAC
TemperatureCoefcient %/°C <0.02%/°C
OvercurrentProtection - 12V:>38A,18V:>26A,24V:>20A,36V:>13,48V:>9.7A
OvervoltageProtection(4) V 12V:13.8-16.2V,18V:20.7-24.3V,24V:27.6-32.4V,36V:41.4-48.6V,48V:55.2-64.8V
HoldUpTime(115/230Vinput) ms 20msat350Woutput
LeakageCurrent mA <0.3mA
Remote Sense - Yes
RemoteOn/Off - Yes:Applyvoltagetoisolatedterminalstoshutunitdown
PowerGood - Yes:Isolatedtransistor,On=Good
OperatingTemperature °C -20°Cto+70°CDeratelinearlyto50%loadfrom40°Cto70°C
StorageTemperature °C -40°Cto+85°C
Humidity(noncondensing) %RH 10-95%RH(Operating&Storage)
Cooling - ConvectionorForcedAirCooled
WithstandVoltage - InputtoGround2kVAC(1xMOPP),InputtoOutput4kVAC(2xMOPPs),
OutputtoGround1.5kVAC(1xMOPP)*
IsolationResistance - >100MΩat25°C&70%RH,OutputtoGround500VDC
Vibration(nonoperating) - 10-55Hz:19.6m/s
2
constantsweep1minX,Y,Zfor1hour
Shock - <196.1m/s
2
(20G)
Immunity - IEC61000-4-2(lv2,3),-3(lv3),-4(lv3),-5(lv3,4),-6(lv3),-8(lv4),-11,EN60601-1-2;2015(Ed4)
SafetyAgencyCertications - EN/IEC/UL/ES/CSA60601-1,EN/IEC/UL/CSA60950-1,CEMark
Conducted&RadiatedEMI - EN55011-B,FCCClassB(RadiatedClassA)
Weight(Typ) g 850
Size(LxWxH) mm 190x87x40
Warranty yrs 3
0HGLFDO
Notes:
(1)Deratelinearlyto80%loadfrom115to85VACinput
(2) 115/230VACinput
(3)Referstoinputpowerduringremoteoffandstandby,5V&12Vfansupplyatnoloadconditions
(4)CycleACtoreset
*
Suitable for B & BF rated medical equipment