Datasheet

CUS200M Series
,QGXVWULDO 7HVW
Single Output 200 to 250W Medical
& ITE Power Supplies
CUS200M Series
1
www.emea.tdk-lambda.com/cus200m
&RPP
%URDGFDVW
Features Benets
•IEC60601-1(2xMOPP)&IEC60950-1Approvals •SuitableforB&BFtypeMedicalandITEApplications
•200WConvectioncooledrating •Nofannoise,goodfornoise-sensitiveenvironments
•Lowprole(34mm),Standard3”x5”format •Spacesaving&easysystemintegration
•5VStandbypowersupplyonboard •Noadditionalcircuitryneeded,savescost
•OperatingAltitudeupto5000m •Supportsglobaluse&globalsalesofequipment
•HighEfciencyupto94%,Lowoff-load •Excellent“environmentalfootprint”
powerconsumption(<0.5W)
Specication
Model CUS200M
ACInputVoltage VAC 85-265VAC(1)
InputFrequency Hz 47-63Hz
InrushCurrent(coldstart) A 35Aat115VAC,70Aat230VAC
PowerFactor - MeetsEN61000-3-2ClassA(TypicalPF0.99/0.95)(2)
InputCurrent(115/230VAC) A 200Woutput:2.2/1.1A;250Woutput:3.0/1.5A
Off-loadPowerConsumption(3) W <0.5Wat230VAC
TemperatureCoefcient %/°C <0.02%/°C
OvercurrentProtection - 12V:>17.2A,18V:>14.7A,24V:>11A,36V:>7.4A,48V:>5.5A
OvervoltageProtection(4) V 12V:13.2-16.2V,18V:19.8-24.3V,24V:26.4-32.4V,36V:39.6-48.6V,48V:52.8-64.8V
HoldUpTime(115/230Vinput) ms 16msat200Woutput,12msat250W
LeakageCurrent mA <0.3mAat265VAC,60Hz
RemoteOn/Off - Applyvoltagetoisolatedterminalstoshutunitdown
PowerGood - Isolatedtransistor,On=Good.Gives>5mswarningofACpowerloss
StandbyVoltage - 5V0.6A(convection),1A(forcedair)
OperatingTemperature °C -20°Cto+70°C.Deratelinearlyto50%loadfrom+50°Cto+70°C
StorageTemperature °C -40°Cto+85°C
Humidity(noncondensing) %RH 10-95%RH(Operating&Storage)
Cooling - ConvectionorForcedAirCooled(1.5m/sacrossterminals)
WithstandVoltage - InputtoGround2kVAC(1xMOPP),InputtoOutput4kVAC(2xMOPPs),OutputtoGround
1.5kVAC(1xMOPP)SuitableforBandBFratedmedicalequipment
IsolationResistance Ω >100MΩat25°C&70%RH,OutputtoGround500VDC
Vibration(nonoperating) - 10-55Hz:19.6m/s
2
constantsweep1minX,Y,Zfor1hour
Shock - <196.1m/s
2
(20G)
Immunity - IEC61000-4-2(lv2,3),-3(lv3),-4(lv3),-5(lv3,4),-6(lv3),-8(lv4),-11,EN60601-1-2:2015(Ed4)
SafetyAgencyCertications - EN/IEC/UL/ES/CSA60601-1,EN/IEC/UL/CSA60950-1,CEMark
Conducted&RadiatedEMI - EN55011-B,FCCClassB
Weight(Typ) g 350
Size(LxWxH) mm 127x76.2x34
Warranty yrs 3
0HGLFDO
Notes:
(1) Deratelinearlyto80%loadfrom115to85VACinput
(2) 115/230VACinput
(3) Referstoinputpowerduringremoteoffandstandby5Vinatnoloadcondition 
(4) CycleACtoreset

Summary of content (6 pages)