Datasheet
TDK-Lambda
CUS200M
SPECIFICATIONS
CA811-01-01A
MODEL  
ITEMS
1  Nominal Output Voltage V 12
 Maximum Output Current @ Convection cooling A 16.7
 Maximum Output Current @ Forced air cooling (*12) A 16.7
 Maximum Output Power @ Convection cooling W 200.4
 Maximum Output Power @ Forced air cooling
(*12)
W
200.4
4  Standby Mode Power -
 Efficiency @ Convection cooling (Typ.) 115/230 VAC (*1) % 92 / 93
 Efficiency @ Forced air cooling (Typ.)  115/230 VAC (*1) % 91 / 93
6  Input Voltage Range (*2) -
 Input Current @ Convection cooling (Typ.)  115/230 VAC (*1) A
 Input Current @ Forced air cooling (Typ.)  115/230 VAC (*1) A
8  In-rush Current (Typ.)  115/230 VAC (*1)(*3) -
9
-
10  Power Factor (Typ.) 115/230 VAC (*1) -
11  Output Voltage Range V 11.7 ~ 12.6
 Maximum Ripple & Noise@ Convection cooling  
115/230 VAC(*1)(*4)(*5)
mV 180
 Maximum Ripple & Noise@ Forced air cooling
115/230 VAC(*1)(*4)(*5)
mV 180
13  Maximum Line Regulation (*4)(*6) mV 60
14  Maximum Load Regulation (*4)(*7) mV 120
15  Remote Off Power Consumption (*13) -
16  Temperature Coefficient (*4) -
17  Over Current Protection  (*8) A >17.5
18  Over Voltage Protection  (*9) V 13.2 - 16.2
19  Hold-up time (Typ.)    (*1) -
20  Leakage Current (*10) -
21  Remote ON/OFF control -
22  DC-OK
23  Parallel Operation  -
24  Series Operation -
25  Operating Temperature  (*11) -
26  Operating Humidity -
27  Storage Temperature -
28  Storage Humidity -
29  Cooling (*12) -
31  Isolation Resistance -
33  Shock -
35  EMI (*1) -
36  Immunity -
37  Weight (Typ.) g
38  Size ( L x W x H ) mm
 *Read instruction manual carefully, before using the power supply unit.
 =NOTES=
 *1.Ta=25
℃
, Nominal output voltage and maximum output power.
 *2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
 input voltage range will be 100 ~ 240VAC (50-60Hz). 
 Output derating required when Vin is less than 115VAC, refer to output derating curve for details.
 *3. Not applicable for the in-rush current to Noise Filter for less than 0.2ms.
 *4. Please refer to Fig. A for measurement of Vo, line and load regulation and ripple voltage.
 *5. Ripple & noise are measured at 20MHz by using a 150mm twisted pair of load wires terminated with a
 0.1uF and 100uF capacitor.
 *6. 85~265VAC, constant load.
 *7. No load - full load, constant input voltage.
 *8. Hiccup with automatic recovery,however power supply may be latched for protection when output is shorted
 and manual reset is required (Repower on) . 
 Avoid to operate at over load or short circuit condition for more than 30 seconds.
 *9. OVP circuit shut down the output, manual reset (Repower on) to get output voltage.
 *10. Measured by the each measuring method of UL, CSA, and EN (at 60Hz), Ta=25°C. 
 *11. Refer to Output Derating Curve for details of output derating versus
 input voltage, ambient temperature and mounting method .
 - Load (%) is percent of maximum output power or maximum output current.
 Do not exceed its derating of Maximum Load.
- maximum load start up at -40°C is possible. However, it may not fulfill all the specifications.
 *12. Forced air cooling with air velocity more than 1.5m/s and air volume more than 15.9CFM (measured at component side, air must flow through component side).
 *13. The power consumption refers to input power during remote off and standby 5V is at no load condition.
52.8 - 64.819.8 - 24.3
Less than 196m/s
2 
and MIL-STD-810F
Approved by IEC60601-1 2nd Edition and 3rd Edition, EN60601-1 3rd Edition,
ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No.60601-1 3rd Edition(cTUVus),
IEC/EN60950-1 2nd Edition, UL/CSA60950-1 2nd Edition(cTUVus ),
Design to meet GB4943.1
10 - 95%RH (No condensing)
34
 Vibration
-
 Withstand Voltage 
-
-
 Safety
90 120
47 ~ 50.4
32
30
240
<0.5W @ 230VAC 
16ms @ 200W, 12ms @ 250W
480
-
480
>14.7 > 11 >5.5
Maximum 19.6m/s
2
 X,Y,Z 1 hour each
240
Convection or Forced Air Cooling
 10 - 95%RH (No condensing)
Possible
26.4 - 32.4
More than 100MΩ at 25°C,70%RH, Output - FG : 500VDC
 Input-Output : 4kVAC (20mA) 2x MOPPs
Input-FG : 2kVAC (20mA) 1x MOPP
-40°C - +85°C
Output-FG : 1.5kVAC (20mA) 1xMOPP
Designed to meet IEC61000-4-2 (Level 2,3), IEC61000-4-3 (Level 3),
IEC61000-4-4 (Level 3), IEC61000-4-5 (Level 3,4),
 IEC61000-4-6 (Level 3), IEC61000-4-8 (Level 4), IEC61000-4-11
127 x 76.2 x 34 (Refer to Outline Drawing)
Possible
Less than 0.02% / ℃
Possible
0.3mA max @ 265VAC,60Hz
180
350
Designed to meet EN55011-B, EN55022-B, FCC-Class B @ Convection cooling
-20℃- +70℃
At no operating, 10-55Hz (Sweep for 1min.)
92 / 94
92 / 94
201.6
11.2
254.4
23.5 ~ 25.2
92 / 94
252.0
85 - 265 VAC (47-63Hz) 
 PFHC        Built to meet IEC61000-3-2,Class A
201.6
17.6 ~ 18.9
24 48
8.4 4.2
2.2/ 1.1
3.0/ 1.5
5
92 / 94
201.6
92 / 94
5V @ 0.6A(max) at convection cooling, 5V @ 1A(max) at forced air cooling
CUS200M-18CUS200M-12 CUS200M-24 CUS200M-48
18
35A / 70A at Cold Start
200 240 480
240180
12
10.5 5.3
0.99/0.95
2
7
252.0
3
14.0
92 / 94
Output Terminal
Measurement point for Vo Line/Load Regulation
Measurement point for Ripple and Noise
47μ 0.1μ
150mm
Fig.A
A
-V
+V
100 µ
V-
V+