Datasheet

Critical component maximum allowable temperature table
Circuitreference Description Maximumtemperature(˚C)
L1 Commonmodechoke 110(130)
L2 PFCchoke 125(130)
L3 Differentialmodechoke 125(130)
C1 Filmcapacitor 105
C2,C110 Electrolyticcapacitors 86(105)
C6,C102,C104,C105 Electrolyticcapacitors 92(105)
C3 Xcapacitor 100
C5,C100,C101,C103 Ycapacitor 105
TX100 Transformerwinding 110
XU101,XU102 Opto-coupler 100(110)
XD8 Diode 130
J1 Inputconnector 105
J100 Outputconnector 105
Thehighertemperaturelimitsshowninbracketsmaybeusedbutproductlifemaybereduced Note: Please refer to installation handbook for full details
CUS150M Series
8