Datasheet

CUS100ME Series
3
Immunity Levels
Test Standard Test Level Criteria
Notes
The power stated below is total power
(main output + fan output)
ESD EN61000-4-2 4 A
Radiated Susceptibility EN61000-4-3 3 A incproximityeldrequirementsofEN60601-1-2:2015
Electrical Fast Transient Burst EN61000-4-4 4 A (ACPort,5kHzand100KHz)
Surge EN61000-4-5 3 A -
Conducted Susceptibility EN61000-4-6 3 A -
Magneticelds EN61000-4-8 4 A -
0%for1/2cycle A -
EN61000-4-11 0%for1cycle A -
Class3Industrial 40%for10/12cycles B -
incEN55024 70%for25/30cycles A -
(100VAC) 80%for250/300cycles A -
0%for250/300cycles B -
0%for1/2cycle A -
EN61000-4-11 0%for1cycle A -
Voltage Dips Class3Industrial 40%for10/12cycles A -
& Interruptions incEN55024 70%for25/30cycles A -
(240VAC) 80%for250/300cycles A -
0%for250/300cycles B -
0%for1/2cycle A -
EN60601-1-2:2015 0%for1cycle A -
(100VAC) 70%for25/30cycles A -
0%for250/300cycles B -
0%for1/2cycle A -
EN60601-1-2:2015 0%for1cycle A -
(240VAC) 70%for25/30cycles A -
0%for250/300cycles B -
Ringwave Test EN61000-4-12 3 A -
Voltage Fluctuations EN61000-4-14 Class3 A -
CriteriaAdenition:theoutputstayswithin+/-5%ofregulation
Examples; CUS100ME-24/UEM,CUS100ME-12V5/A
Part Numbering Scheme
CUS100ME- 12 / U E M
Output voltage 12, 15, 18, 24, 28, 36, 48
(theseoptionssubjecttoMOQ,pleaseconsultSales)
blank open pcb
U U channel
A U channel with cover
B baseplate
blank dual fuses
E Single input fuse in line line
blank JST connectors
M Molex connectors