Datasheet
1781-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
CN-A24 Series
Features
 14.4 - 36VDC Input
 IEC 61373 Shock and Vibration 
 Base-plate Cooled
 Full Power at 100°C base plate
 Small Size
 Quarter Brick Footprint
 Wide input range
50 & 100W 14.4 to 36VDC Input DC-DC Converters
  Note: See Installation Manual for full details, test methods of parameters and application notes
  (1) Compliant to EN50155 & IEC60571
Model
  Nominal Output Voltage  VDC  5V  12V  24V
  Input Voltage Range  VDC    14.4 - 36VDC (40V transient for 3 seconds)
  Input Current  A    2.48 - 4.91A (model dependant)
  Output Voltage Adjustment  VDC  4.5 - 6  10.8 - 13.2  21.6 - 26.4
  Ripple & Noise (max) pk-pk  mV  100  150  240
  Line Regulation (max)  mV  20  48  96
  Load Regulation (max)  mV  40  96  192
  Overcurrent Protection  %  105 - 140%
  Overvoltage Protection  %  125 - 145% (Cycle input or remote on/off to reset)
 Remote Sense  -  Yes
  Remote On/Off  -  Yes; Low = ON, Open = OFF
  Operating Temperature  °C  -40°C to +100°C Baseplate
  Storage Temperature  °C  -40°C to +100°C
 Temperature Coeffi cient  %/°C  0.02%/°C
  Humidity (non condensing)  %RH  5 - 95% RH Operating and Non Operating
  Cooling  -  Conduction (See Installation Manual for heatsink selection)
 Withstand Voltage  VAC  Input to Base-plate: 2kVAC; Input to Output 3.0kVAC for I min.; Output to Base-plate: 500VAC for 1 min 
  Isolation Resistance  -  >100M at 25C and 70%RH, Output to Base plate 500VDC
  Vibration (1)  -  Non Operating, 10-55Hz (sweep for 1 min.)
      Amplitude 0.825mm constant (Max 49 m/s
2
) X,Y,Z 1 hour each
      IEC61373 - Category 1, Grade B
  Shock (1)  -  196.1m/s
2
, IEC61373 - Category 1, Grade B
 Safety Agency Certifi cations  -  UL60950-1, CSA60950-1, EN60950-1
 Weight (Typ)  g  70g
  Size (WxHxD)  in(mm)  1.45 x 0.5 x 2.28” (36.8 x 12.7 x 57.9)
 Warranty  yrs  5 Years
Specifi cations
Key Market Segments & Applications