Information
INSTRUCTION MANUAL
RWS 50B600B Series
TDKLambda
TDKLambda
7/24
CCG1548**D
1. Regulation line and load
Condition Ta : 25 ºC
・
+Vo
Io \ Vin 18VDC 24VDC 48VDC 76VDC Line regulation
0% 15.071V 15.076V 15.073V 15.083V 12mV
50% 15.056V 15.057V 15.057V 15.055V 2mV
100% 15.058V 15.055V 15.053V 15.050V 8mV
15mV 21mV 20mV 33mV
0.100% 0.140% 0.133% 0.220%
・
Vo
Io \ Vin 18VDC 24VDC 48VDC 76VDC Line regulation
0% 15.050V 15.046V 15.048V 15.040V 10mV
50% 15.063V 15.065V 15.064V 15.062V 3mV
100% 15.060V 15.065V 15.067V 15.064V 7mV
13mV 19mV 19mV 24mV
0.087% 0.127% 0.127% 0.160%
・
+Vo to Vo
Io \ Vin 18VDC 24VDC 48VDC 76VDC Line regulation
0% 30.120V 30.122V 30.121V 30.123V 3mV
50%
30.119V 30.121V 30.121V 30.117V
4mV
100%
30.118V 30.120V 30.120V 30.114V
6mV
2mV 2mV 1mV 9mV
0.013% 0.013% 0.007% 0.060%
2. Temperature drift
Conditions Vin : 48 VDC
Io : 100 %
Ta
40
o
C
25
o
C
85
o
C
Temperature stability
+Vo 15.053V 15.053V 15.078V 25mV 0.167%
Vo 15.070V 15.067V 15.092V 25mV 0.167%
+Vo to Vo 30.123V 30.120V 30.170V 50mV 0.333%
3. Load Regulation Unbalance load
Conditions Ta : 25 ºC
・
Io : 100%
+Io \ Vin 18VDC 24VDC 48VDC 76VDC
20% 15.211V 15.208V 15.208V 15.205V
100% 15.071V 15.067V 15.065V 15.062V
140mV 141mV 143mV 143mV
0.933% 0.940% 0.953% 0.953%
・
+Io : 100%
Io \ Vin 18VDC 24VDC 48VDC 76VDC
20% 15.193V 15.194V 15.195V 15.194V
100% 15.071V 15.076V 15.079V 15.077V
122mV 118mV 116mV 117mV
0.813% 0.787% 0.773% 0.780%
±15V
0.080%
0.013%
0.053%
Load
regulation
0.067%
0.020%
0.047%
Load
regulation
0.020%
0.027%
0.040%
Load
regulation
Load
regulation
Load
regulation