(5) Acceptable Conditions
1.試験中、5%を超える出力電圧の変動のない事
The regulation of output voltage must not exceed 5% of initial value during test.
2.試験後の出力電圧は初期値から変動していない事
The output voltage must be within the regulation of specification after the test.
3.発煙・発火のない事
Smoke and fire are not allowed.
(6)
Test Circuit
• 電界コンデンサ (C1) : 50V 120µF
Electrolytic Cap.
• セラミックコンデンサ (C2) : 25V 22µF
Ceramic Cap.
(7)
Test Result
CCG1524**S
CCG1524**S
Contact Discharge (kV)
8
CCG152405S
PASS
CCG152412S
PASS
Air Discharge (kV)
8
CCG152405S
PASS
CCG152412S
PASS
Fuse
6.3 A
C1
C2
+Vin
RC
Vin
+Vout
TRM
Vout
Load