Information

INSTRUCTION MANUAL
RWS 50B600B Series
TDKLambda
TDKLambda
22/23
CCG1524**S
10.
High Temperature and High Humidity Bias Test
MODEL : CCG152405S
(1)
Equipment Used
TEMP.HUMID. CHAMBER PR1KH (ESPEC CORP.)
(2) The Number of D.U.T. (Device Under Test)
CCG152405S 1 (unit)
(3) Test Conditions
・周囲温度 85ºC
Ambient Temperature
・湿度 85%
Humidity
・試験時間 500 時間
Test time 500 hours
・入力電圧 : 0VDC 24VDC
Input Voltage
・出力電圧
Output Voltage Rated
・出力電流 : 0A (0% )
Output Current
(4)
Test Method
初期測定の後、供試体を試験槽に入れ、槽の温度を室温(25ºC)ら周囲温度が規定温度(85ºC)
になるまで徐々に上げる。 供試体を規定の条件に500時間試験を行い、常温常湿下に1時間放
した後、出力に異常がない事を確認する。
Check if there is no abnormal output before test. Then fix the D.U.T. in testing chamber, and the
ambient temperature is gradually increased from 25ºC to 85ºC. Test the D.U.T for 500 hours
according to above conditions and leave D.U.T. for 1 hour at the room temperature, then check
if there is no abnormal output.
Input Voltage
24VDC
Input Voltage
0VDC
3hours
1hour
4hours