Datasheet

No. MATERIAL NAME
MATERIAL REMARKS
PRODUCT NAME or MODEL,TITLE
DC-DC CONVERTER UNIT CC10-xxxxxR-E Series
PAGENAME OF DRAWING DRAWING No.
PRODUCT SPECIFICATIONS TRSA-0289-3 /
TDK CORPORATION
QU
17
Product
CC10-05xxxR-E
CC10-12xxxR-E
CC10-24xxxR-E
CC10-48xxxR-E
Low Input Voltage Protection
Setting Range
3.3-4.5V
6.0-9.0V
13.0-18.0V
27.0-36.0V
Product
CC10-05xxxR-E
CC10-12xxxR-E
CC10-24xxxR-E
CC10-48xxxR-E
Rated Current
10A
5A
2.5A
1.25A
Fusing Current
20A or more
10A or more
5A or more
2.5A or more
12
8-7. Input Circuit Protection :
The converters are equipped with input fuse. Fuses rating and capacity are shown in below table
8-3. Output Over Current Protection (OCP) :
OCP is activated when output Over Current (OC) is detected (105 to 250% of nominal output current) .
Converter is auto recovery, if OC is removed.
However, manual recovery is necessary if OC condition continues for more than 30 sec.
If auto recovery is not activated for some reason, please shout off the converter and restart the converter.
If you require the converter to be latched up during over current condition, please consult your
TDK representative for recommendation of adding an external circuitry to RC terminal.
8-4. Output Over Voltage Protection :
This converter does not have an output over voltage protection function.
Consult your TDK representative for recommendation of adding external circuitry to RC terminal.
8-5. Output Under Voltage Protection :
This converter does not have an output over voltage protection function.
Consult your TDK representative for recommendation of adding external circuitry to RC terminal.
8-6. Under Voltage Lock out :
This product is equipped with a low input voltage protection circuit in order to prevent miss-operation when the
input voltage is low. The converter stops operating when it falls below the voltage setting. The setting range is
shown in the table below.