23
Calculating connected resistance Ra, Rb (kΩ) from set out-
put voltage Vout (V)
Adding a resistance Ra between TRM terminal and -Vout 
terminal, to set the output voltage high
*1 Ra = 1.04/(Vout-3.3) - 2.83
*2 Ra = 12.75/(Vout-5) - 12.69
*3 Ra = 48.4/(Vout-12) - 16.18
*4 Ra = 54.7/(Vout-12) - 18
Adding  a  resistance  Rb  between  TRM  terminal  and 
+Vout terminal, to set the output voltage low
*5 Rb = 1.69/(3.3-Vout) - 3.66
*6 Rb = 12.78/(5-Vout) - 17.79
*7 Rb = 184.1/(12-Vout) - 35.54
*8 Rb = 470.3/(12-Vout) - 61.75
41.giF31.giF
61.giF51.giF
+Vout
TRM
–Vout
Load
Ra
3.3∼3.67V、5∼6V、12∼15V
Load
Rb
+Vout
TRM
–Vout
3.15∼3.3V、4.75∼5V、11.4∼12V
+Vout
TRM
–Vout
Load
Load
COM
Ra
+12∼+15V –12∼–15V
+Vout
TRM
–Vout
Load Load
COM
Rb
+11.4∼+12V
–11.4∼–12V
*1,*2, *3 *5,*6, *7
*4 *8
1-4. Over current protection
1.5-10W type
An over  current protection  circuit is  incorporated  in  the 
model,  and if  over  current  occurs,  the  output voltage  is 
lowered. By removing the  over current and shorted condi-
tions, the output voltage automatically resumes. Note that 
if the over current status continues for 30 seconds or over, 
the internal elements of the converter may be deteriorated 
or damaged. The current value, from which it is judged as 
an over current, is not to be lower than the nominal current 
value. If the output voltage does not resume even after re-
moving the over current conditions and any causes, turn off 
the power or remote control once, and then restart it.
15/25W type
An over  current protection  circuit is  incorporated  in  the 
model,  and if  over  current  occurs,  the  output voltage  is 
lowered and  the converter  is  stopped  and latched. The 
output  voltage does  not automatically resume even  after 
removing the over current and shorted conditions.
To resume output voltage, restart input or reset remote on/
off.
The current value, from which it is judged as an over cur-
rent, is not to be lower than the nominal current value.
1-5. Over voltage protection
An over voltage protection function is not incorporated  in 
the model. Be careful if an external voltage over the nomi-
nal voltage is applied, damage may be caused.
1-6. 
Low input voltage protection
This series is equipped with the low input voltage protec-
tion in order to prevent malfunction due to low input  volt-
age.  The  converter  stops  operation if the  input  voltage 
become lower  than the  set  voltage.  The  set  ranges are 
shown in the table below.
Model name  Input voltage range 
Voltage range set for protection circuit
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
to
to
to
to
to
to
to
to
to
to
to
to
1-7. Insulation withstand voltage
The insulation withstand voltage between input and output, 
and between terminal and case, is AC500V.
1-8. Series/Parallel connections
Series connection
Serial connection is applicable by wiring as shown in the 
figure below (left). If output voltage is not generated by this 
connection, connect a Schottky diode in which the forward 
voltage is possibly low.
Also  note that the Schottky  diode should  have a  reverse 
voltage  that  is twice or over the  value  of the  voltage be-
tween +Vout and -Vout.
And the output current should be  the same or  lower than 
the nominal current value, whichever is smaller in the con-
verters.
+Vin +Vout
–Vin –Vout
+Vin +Vout
–Vin –Vout
+Vin +Vout
–Vin –Vout
+Vin +Vout
–Vin –Vout
Load
Load
Parallel connection
Parallel connection is not applicable.