Instructions
6. Other settings
The   following   functions   can  be   activated  independently  by   short-circuiting
connectors J1-J3 by jumper or switch during operation:
J1: Graphical historic data display
To   activate   the   graphical   historic   data
display  connector  J1   is   shorted.  The   unit
displays   the   stored   values   within   the   set
time base as a graphical trend.
The time base  can be  set to  days  (7, 14),
hours (6, 12, 24, 48, 72) or minutes (3, 15,
30, 60).
The   time   base  can  be   changed   by
alternately opening and closing J1 (interval
< 2 sec). When first opening and closing J1
the  current   time   base  is   displayed.  For
each subsequent  opening and closing the
time base  changes  to the next setting.  In
order to save the setting  permanently, DIP
switch   10   must   be   switched   from   ON   to
OFF position.
J2: Min-Max-display
To activate the Min-Max display connector
J2   is   shorted.   The   display   shows   the
maximum   and   minimum   values   recorded
since   the   last   reset.   The   values   can   be
reset by opening and closing connection J2
shortly   (interval   <   2   sec).   The   display
shows "Minmax reset".
J3: Auto-scaling
To   activate   auto-scaling   J3   connector   is
shorted. The device automatically changes
the upper scale caption depending on the
current measuring value between 10, 100
and the set upper scale caption.