Instructions
3. Description
The measurement modes analogue signal 0/2 to 10 V and 0/4 to 20 mA DC are
supported. The multi display is able to display two parameters simultaneously.
Thresholds can be associated with individual warning colours. Minimum and
maximum values are recorded and can be displayed and reset via jumper or an
external switch. Measured values of one parameter are recorded over a timespan of 3
minutes up to 14 days. The timebase as well as the display of the measuring history
can be activated by an external switch. The measured values remain stored as long
as the device is supplied with voltage.
The following parameters can be adjusted using the USB configuration software:
scale endpoint, scale caption, display style (pointer, tachometer, bar graph, and
more), splash image, backlight colour, thresholds for alarm output, threshold warning
colour (light, blink), hysteresis, and more. Recorded measurement values can be read
and a continuous transmission of the actual measuring value can be enabled. Using
the software, values can be viewed and exported as CSV.
Front
1 Unit or free text
2 Threshold values
3 Upper scale caption
4 Graphical measurement display
5 Digital measurement value
6 Lower scale caption
Back
1 2 optocoupler switch outputs
2 DIP switch for setting measurement
mode and upper scale caption
3 Supply voltage input
4 Jumper pins J1 – J6 for
activating/switching of
measurement mode, graphical
historic data display, min/max
display, auto-scaling
5 USB interface for alternative power
supply and software communication
interface
6 Measurement inputs
----- 2 -----