Instructions

3" ?$
Connect the device to a computer:
>#9 Connect the device and the computer using a USB cable. The
device driver is installed automatically if the computer is connected to
the Internet.
B9;; Insert the XBEE stick into the computer. The device driver is
installed automatically if the computer is connected to the Internet. In
order to reset the XBEE settings, short-circuit terminal J8.
#536 Short-circuit terminal J8. Connect the device to the computer
using an RS485 USB adapter. After completing the configuration,
open J8 again.
Start the "Digalox Manager" software and connect it to the device. Settings can
then be made on the various tabs and saved in the device.
Please note that the measurement mode selected in “Digalox Manager” is displayed
only until the power supply of the DPM72 is interrupted.
$*+@*,.%*.*$
,**,0%*C+
151:0D,E@
$,+%%,,%*$.,"
)0,$%+@0*,0%$.
, +% ,

1 V DC direct Volt DC
1!
1!
2 A DC direct Ampere DC
3 P DC direct Watt DC
4 V AC direct Volt AC
5 A AC scaled (with shunt) Ampere CT
6 P AC scaled (with shunt) Watt CT
7 AC Frequency Freq. AC
 When using a multi display style, AC and DC measurement cannot be done
simultaneously. The first measurement mode used defines the type of
measurement.
-----623-----