Instructions
4 /
The device can be configured via DIP switches and jumpers manually or with the
corresponding software “Digalox Manager” via USB interface. When configuring via
DIP switches and jumpers the basic settings can be made computer-independent.
The configuration with the software “Digalox Manager” allows full functionality.
%#
In modes where a scaling is necessary to represent the correct measurement value
(e.g. 5$A AC for current transformer) the upper scale value corresponds to the
primary value of the current transformer or shunt.
Example:
upper scale value = 50 = primary value of the current transformer
/%,#;<
For configuration with software set DIP switch 10 to OFF position.
Please note that the measurement mode selected in "Digalox Manager" is displayed
only until the power supply of the DPM72 is interrupted.
#$3#% ##3
##) #=$9-9:##
$% &
6)>>7
/%#=$
?67
1. Set DIP switch 10 to ON position.
2. Set measurement mode with jumpers at J4-J6 according to table "Measurement
mode”, column “Manual mode".
3. Set upper scale caption for the first measurement mode with DIP switches 1-9
(see “Configuration of the upper scale caption”).
4. Connect supply voltage.
----- - -----