User Manual

24 System Installation PLUS System Manual
Proprietary Information: Do not disclose unless authorized under a Nondisclosure Agreement and the Partner Agreement.
2.3.6 Server Setup and Software Installation
The following steps describe the process of connecting to a server through an Ethernet switch,
configuring server network settings, and installing the PLUS software.
2.3.6.1 Connecting the SDP, Ethernet Switch, and Server
The Ethernet traffic on each SDP ―LAN IN‖ port is isolated from all other ―LAN IN‖ ports and must
be routed through an Ethernet switch to the server. Very small installations may be able to use an
Ethernet hub to connect to the network, but larger installations should use an Ethernet switch that
meets the minimum specifications to avoid data loss.
For each SDP ―SYNC OUT‖ port that is connected to a Reader chain, connect the corresponding
―LAN IN‖ port to the Ethernet switch. Standard CAT 5 cable may be used. Be sure that the cable
snaps firmly into place.
Connect one port on the Ethernet switch to the server NIC that will be handling tracking network
data.
Loose cable connections at the SDP can be costly in terms of time spent troubleshooting. If a
cable will not plug securely into the SDP, correct the problem before continuing with the
installation.
2.3.6.2 Server IP Address Configuration
The server that will be used to run the PLUS Software should be equipped with a NIC card dedicated
to the tracking network. Set the IP address to match the Location Engine address configured on the
Readers. The example below demonstrates configuration of a NIC card with IP address 10.1.4.1 and
subnet mask of 255.255.255.0.
Figure 2-16: TCP/IP Properties