User Manual

PLUS System Manual Visualizer 129
Proprietary Information: Do not disclose unless authorized under a Nondisclosure Agreement and the Partner Agreement.
5.8 Logfile Formats
5.8.1 Position Data
The Position Data is logged to the file specified via the Menu Bar / File / Logging… submenu item.
See Section 5.2 Menu Bar.
5.8.1.1 Position Data Record
Position data records are the timestamped Tag positions as computed by the PLUS location engine.
Timestamp Time the position data was recorded, represented as the number of 100-
nanosecond intervals since January 1, 1601 (64 bits)
TAGPOS Record type TAGPOS
tagID ID of the Tag whose position is being reported
X X coordinate of the solution
Y Y coordinate of the solution
Z Z coordinate of the solution
NumReceivers Number of receivers which participated in the solution, i.e. heard the Tag
Confidence Percent confidence factor for the solution the higher the factor the greater the
confidence of the solution
SeqNum Sequence number from the Tag payload that cycles from 0 to 63
Best Receiver ID of the Reader with the best TOA solution statistical weight based on
Reader RSSI and proximity to the Tag.
5.9 Troubleshooting the Visualizer
Lost contact with a Reader
Lost Reader contact usually occurs due to network based problems. Check all cables and
connections between:
1) The PC and the SDP
2) The SDP and its connected Readers
3) Any daisy chained Readers
If all connections are good, reboot the Reader, or reset the power to the PLUS Reader itself. See
# Timestamp, TAGPOS, tagID, X, Y, Z, NumReceivers, Confidence, SeqNum, Best Receiver
# All times are in seconds and coordinates in meters
0x01c82081c13356c6, TAGPOS, 0x00000651, 3.925, -5.427, 1.359, 14, 57, 6, 0x0050c216af90
0x01c82081c13ce022, TAGPOS, 0x0000065a, 2.992, -4.300, 1.148, 15, 76, 52, 0x0050c216afe5
o 0x01c82081c1630592, TAGPOS, 0x0000086e, -2.936, -1.450, 1.338, 16, 64, 8, 0x0050c216afe5