4) Select the Start button in the Calibration dialog. A progress bar will denote the status of the
calibration process. If you wish to stop calibration before it is complete, select the Stop button.
5) Review the results of the calibration. Select OK to apply the new results if they are satisfactory.
Translate Select this button to dynamically rotate and/or translate the Reader coordinate system
into the coordinate system of the graphical display. NOTE that the Z value is not currently
selectable.
o Use the dial to define the rotation
o Use either the slider or key-in field to set the X and Y values for translation.
Figure 5-24: Translate Dialog
Tags Select this button to change the List View to ―tag view‖ mode. In this mode, the List View
shows status of the Tags.
Figure 5-25: Tag List View
Readers Select this button to change the List View to ―Reader view‖ mode. In this mode, the
List View shows status of the Readers.
Figure 5-26: Reader List View