Data Sheet

DEVICE OVERVIEW
NOTES ON THE INSTRUCTION
The installation guide refers exclusively to qualified elec-
tricians. Please scan the QR Code for detailed informati-
on or go to: tcsag.de/download.
The installation guide contains important notes on the in-
tended use, installation and commissioning of the product.
Please keep the installation guide in a suitable place where
it can be easily accessed for maintenance and repair works.
SAFETY INSTRUCTION
General safety instruction
Assembly, installation, commissioning and repair of
electronic devices must be carried out by qualified
electricians. Observe the latest regulations and standards
for system installations.
WARNING! Danger due to electric shock.
Observe the safety regulations according to DIN VDE
0100, when working on main power connections of 230 V.
When installing TCS:BUS systems the general safety
regulations for telecommunication systems according
to VDE 0800 must be observed. Inter alia:
> separated cable routing of high and low voltage lines,
> minimum distance of 10 cm in case of a common cable routing,
> use of separators between high and low voltage lines within
shared cable ducts,
> use of standard telecommunication lines, e.g. J-Y (St) Y with
0.8 mm diameter,
> already existing lines (modernisation) with deviating
cross-sections can be used in compliance with the loop
resistance.
MOUNTING AND INSTALLATION
Mounting height
For an optimal operation, install the indoor station at 1.60 m.
Install the mounting tray
Observe the installation position of mounting tray. It is
marked by an arrow and the designation TOP.
The mounting tray can be installed directly to the wall or on
a flush-mount socket.
Guide the connection cable through the cable gland. Connect
the wires to the terminal (a, b, E, P, P, M, V1 und V2). Fix the
mounting tray
with suitable screws to the wall or on the flush-mount socket.
Connecting the floor push button
Connect the floor push button to the terminals E – P an.
Alternatively you can connect the floor push button to the
terminals a – E. Ensure that the a-wire of the control unit
is connected to the a-terminal of the indoor station.
Snap-on the device on the mounting tray
Put the device onto both adjustment increments (1). Press the
device against the latch until it snaps on (2).
2
1
1
Remove the device from the mounting tray
Insert a screw driver with slight pressure into the release
opening (1). Pull off the device to the front at its upper side.
Lift the device out of the adjustment increments (2).
PRODUCT INFORMATION (brief)
Video indoor station for hands-free talking
Series TASTA
IVW5110-0145
IVW5111-0145
German / English
IVW5110-0145 IVW5111-0145
SCOPE OF DELIVERY
1 x indoor station
1 x mounting tray
1 x installation guide
1 x user manual (brief)
Requirements to protect against lightning
CAUTION! Device damage due to overvoltage.
Secure the low voltage system against overvoltage.
INTENDED USE
IVW511x-0145 is a video indoor station for hands-free talking.
It is suitable exclusively for operation at TCS:BUS. Type of
mounting: suface-mount or as table-top device with desktop
accessory ZIT5000-0030..
The manufacturer accepts no liability for any uses differing
from or exceeding the intended use.
INDICATION AND OPERATING ELEMENTS
1. 3,5 inch Display (8,9 cm)
2. Sensor button colour
> shortly touch: adjustable in 8 steps
3. Sensor button image activation
> shortly touch: video image of the front door camera is
displayed or switching-over between different cameras
4. Microfon
5. Function button
>send control function 8, send internal call, door
release automatic on/off or call diversion on/off confi-
gurable
6. Light switch button
>switch light, send control function 9 or internal call 2
> ring tone selection: floor call (from flat door)
> ambient illumination: press for 4 s, to de-/activate
7. Indication for door release, blue LED
>OFF: door opener in standby
>ON: door release automatic is activated
>ON for 3 sec: door will be opened
8. Door release button
>open the door
> trigger light switch function, if the light switch function is
activated in the front-door station
>quit speaking: voice connection is terminated after 4 sec
automatically
> ring tone selection: door call 1 from front-door station
(ring tone <= ring tone AS)
9. Ambient illumination, LED blue
>OFF: temporary (manually) or permanently switched off
> ON: temporary (manually) or permanently switched on
>blinks: call indication (e.g. door and internal call)
10. Loudspeaker
11. Speech button
>shortly press: call acceptance, speaking is activated
> press for 2 sec: activate simplex communication
> shortly press: quit speaking
> shortly press when selecting ring tones: door call 2
>from the front-door station (ring tone > ring tone AS)
12. Call indication, LED green
>LED off: in standby
>LED on: call, speaking activated
>blinks 3 x: speech channel is busy
13. Volume button
>Setting the ring tone volume in 4 steps, when no voice-
connection is established.
>Setting the volume of the voice output in 4 steps whena
voice connection is established.
14. Smart Slot
>For additional signalling of door calls (can be ordered as
accessory).
15. Call OFF button
>shortly press: ring tone mute is activated
>press for 8 sec: initiate ring tone selection
>shortly press: quit ring tone selection
>press for 2 sec: quit (half-)duplex communication
16. LED indication (red) ring tone mute
>indication call OFF is on: ring tone mute is activated
>OFF: ring tone mute is deactivated
>flashes: call diversion is activated, ring tone mute is de-
activated
>LED turns off in longer periods: call diversion is activa-
ted, ring tone mute is activated
17. Sensor button brightness
>shortly touch: adjustable in 8 steps
18. Sensor button contrast
>shortly touch: adjustable in 8 steps
all LEDs:
>All LEDs are on: ring tone selection is activated
>LEDs flashing: device or TCS:BUS error
2
4
1
3
5
6
7
8
9
18
17
10
12
11
13
14
15
16
1
2
EXCAMPLE CIRCUIT
230 V / 50 Hz
L N
+
-
a b P
230 V / 50 Hz
8 - 24 V
a b E P P
1 3
14 15 16 17
24 23 25
29 31
5 7 9
V1 V2
a b P M V1 V2
M
Fam. Förster
Lilienweg 8
Moosbach
AVC11010
BVS20 | NGV1011
IVW511x-0145
COMMISSIONING
Install all devices of the system completely. Check all wire
against each other on short-circuit. Switch on the mains power.
Fault detection and indication
Faults are signalled optically and acoustically: constant flashing
and when pressing any button, an error tone sounds. The optical
error indication stays active until the error is corrected.
Error tone sounds once long and three times short:
> a- and P-wire are interchanged or short-circuited
> change a- and P-wire or eliminate short-circuit, device is in
stand-by mode again
Error tone sounds once long and twice short:
> a-wire is not connected or not supplied
> connect the a-wire or check power supply, device is in stand-
by mode again
Error tone sounds once long and once short:
>button stucks (press longer than 15 sec)
>remove button at the device or loosen floor push button,
device is in stand-by mode again
BELL BUTTON PROGRAMMING
Requirements for the programming:
>Ensure that the access to the indoor station in the flat is-
granted.
>Check if the indoor station is connected to the TCS:BUS.
>Switch on the mains voltage. The operating LED at the power
supply and control unit is on.
>Check if a programming lock is set. If the programming lock
is activated, you cannot program any bell button. To deactiva-
te the programming lock you need a Service Device TCSK or
the configuration software configo
TM
.
>For device-specific indication modes of the front-door station
see product information of the front-door station.
1. Control unit:
Switching on the programming mode of the sytems
>shortly press the RUN/PROG button
a)
>LED blinks
>programming mode is activated
2. Programming via voice connection
>press the speech button
>shortly press the bell button
>ring tone sounds at the front-door and indoor station
c)
>press the speech or door release button
3. Control unit:
Switching off the programming mode of the system
>shortly press the RUN/PROG button
>LED lights up
>programming mode is deactivated
e)
Deleting bell buttons
b)
>press the bell button that is to be deleted for around 6 sec
until an acknowledgement tone sounds
c)
>release the bell button
>previously execute step 1 and then step 3
NOTES:
a) Do not press the RUN/PROG button longer than 5 sec.
Otherwise you will activate the light switch function of the
front-door station. The bell button cannot be programmed.
Repair:
> If the LED blinks, shortly press the RUN/PROG button to
deactivate the programming mode.
> Press the RUN/PROG button only short to activate the
programming mode.
> Programm the the bell button
b) Not necessary, if the bell buttons have not been programmed,
see product information of the front-door station.
c) If there sounds a Progsperr tone (long high tone followed by
long low tone) instead, the front-door station is equipped with
a programming lock. You can deactivate the programming
lock only with the Service Device TCSK or the configuration
software configo
TM
.
Further information (parallel call with only one bell
button) can be found in the system manual, in the download
area at www.tcsag.de or by scanning the QR code.
MATCHING RESISTOR
If the video indoor station is placed at the end of a strand or
is the only device at the TCS:BUS, the matching resistor is to
be activated.
Ex works the video indoor station is not set up for the
operation at the end of the strand.
J1
aktiviert | activated
deaktiviert | deactivated
PROGRAMMING WITH SERVICE DEVICE TCSK
search device
52
Function button:
call diversion
90 Ser.-Nr. ZielSNr.
automatic door release
91 Ser.-Nr.
intern call
92 Ser.-Nr. IntSNr.
control function 8
93 Ser.-Nr.
Light switch button:
intern call 2
94 Ser.-Nr. IntSNr.
control function 9
95 Ser.-Nr.
light switch
96 Ser.-Nr.
switch ON parallel call
99 Ser.-Nr. ParSNr.
switch OFF parallel call
99 Ser.-Nr. 0
OPERATION
accept/quit a call:
>Shortly press the speech button to accept the call.
>Shortly press the speech button again to terminate the con-
versation.
Door release:
>Shortly press the door release button to open the door. The
conversation is terminated automatically after 4 seconds
Simplex communication de-/activate
>Press the speech button for at least 2 seconds after you have
accepted the call to activate the function simplex communication.
>Press the call OFF button to end the simplex communication
mode.
>Press the speech button to speak.
>Release the speech button to hear your conversation partner.
Adjust volume
Voice output:
>Repeatedly press the volume button until you have adjusted
the required volume for the voice output.
Ring tone:
>Repeatedly press the volume button in stand-by-mode. The
ring tone sounds in the adjusted volume.
Ambient illumination ON/OFF
>Press the Light switch button longer than 4 s.
Ring tone selection
>Press the call OFF button for 8 seconds, when no voice
connection is established. All LEDs are ON and an ack-
nowledgement tone sounds. The different ring tones can be
selected via the different buttons, see indication- and opera-
ting elements.
>Shortly press the call OFF button to end the ring tone selection.
TECHNICAL SPECIFICATIONS
IVW5110-0145 IVW5111-0145
Supply voltage (TCS:BUS supply
unit)
+24 V ± 8 %
6-wire operation
I(a) 0.13 mA
I(P
stndby
) 3.18 mA
I(P
max.
) 147.0 mA
Video module TFT colour
Display size 8,9 cm (3,5 inch)
Resolution 320 x 240 pixel, RGB
Video signal input symmetrical 1 Vss FBAS
Degree of protection IP30
Acceptable ambient temperature - 5 ...+ 40 °C
Housing plastics ASA, white glossy
Dimensions
Height 195 mm
Width 94 mm
Depth 21 mm (with mounting tray)
Weight 227 g
SPARE PARTS, ACCESSORY
Mounting tray .................................................ZIA5006-0145
Desktop accessory ........................................ZIT5000-0030
Radio signal device ........................................FFL2200-0
TASTA surface mounting adapter st.steel ....ZIA5011-0130
NOTES
CONFORMITY
Declarations of conformity are available for download
at www.tcsag.de, Downloads, trade information.
INFORMATION ON DISPOSAL
Dispose the device separately from domestic waste via a collec-
tion point for electronic scrap. Ask your county administration
for the responsible collection point.
Dispose the parts of the packaging in collecting tanks for
cardboard and paper resp. plastics.
WARRANTY
We offer a simplified processing in case of warranty for qua-
lified electricians.
>Please contact the TCS HOTLINE under 4194 9881-188 or
hotline@tcsag.de
>Our standard terms and conditions of sale you‘ll find under
www.tcsag.de, Downloads as well as our current product ca-
talogue.
Service
Please send your questions and inquiries to TCS HOTLINE
04194 9881-188 or hotline@tcsag.de
TCS TürControlSysteme AG
Geschwister-Scholl-Straße 7
D-39307 Genthin
Telefon: +49 3933 8799-10
Fax: +49 3933 8799-11
www.tcsag.de
TCS Österreich GmbH
Gewerbepark 21
A-2821 Lanzenkirchen
Telefon: +43 2627 45266-0
Fax: +43 2627 45266-20
www.tcs-austria.at
Printout: 07/2020 | Subject to technical changes | kPI_IVW511x-0145 8A