Specification Sheet

PO Number:LED0356 Model Number:LED12BR30D30K
Test Results:
Average Beam Angle(50%):
112.2
Directional Lamps - Difinition:
The luminous flux within a solid angle of π sr-Φ1(lumens):
682.2
The total luminous flux-Φ(lumens):
972.2
Φ1/Φ(%): 70.2%
Complies / Does not comply:
Mininum Center Beam Intensity - PAR/MR16 Lamps:
Light Intensity & Color Distribution Tests
No.61, Kaijiang Road(E) Sijing Songjiang Shanghai Tel: (86-21) 57613930 Fax: (86-21) 57619961
TEST REPORT
Directional Lamps
Energy Star Integral LED lamps Specification V1.4:Directional lamp means a lamp having
at least 80% light output within a solid angle of π sr (corresponding to a cone with
angle of 120°)
Does not comply
0
Mininum Center Beam Intensity (cd):
Center Beam Intensity tested (cd):
306
Complies / Does not comply:
Color Spatial Uniformity:
Spatial non-uniformity of chromaticity:
Complies/ Does not Comply:
Light Distribution Polar Diagram:
0.0008
Energy Star Integral LED lamps Specification V1.4:The variation of chromaticity within
the beam angle shall be within 0.006 from the weighted average point on the CIE 1976
(u’,v’) diagram
Complies
This Report shall not be reporduced in part or in full wihout written approval of the Aurora International Testing Laboratory:Shanghai The reports
Does not comply
This
Report
shall
not
be
reporduced
in
part
or
in
full
,
wihout
written
approval
of
the
Aurora
International
Testing
Laboratory:Shanghai
.
The
reports
are submitted for exclusive use of the customers to whom they are addressed. Nothing from these reports or the use of the Aurora International
Testing Laboratory:Shanghai's name is permitted except as expressly authorized be the Aurora International Testing Laboratory:Shanghai.
Page 5 of 5