Obtaining Loudness Pilot status information
Loudness Pilot English Manual (2014-10-07) 46
Please note that the LEDs on the front of a Loud-
ness Pilot will display basic status information as
long as the device is powered – see “Front panel
indicators” on page 24.
Additional status information can be obtained
using TC Icon, where you can also define how
certain error states should be indicated on the
device.
To display status information about Loudness Pi-
lot, go to Frame / System / Status.
Fig. 24.: Loudness Pilot (SDI) Status
page showing various issues
(No Lock, Power supply 2 not
connected, Sync error)
This page will display the following status infor-
mation:
Clock section
Source indicator
Indicates the source of the clock signal Loud-
ness Pilot is currently following.
Lock indicator
Indicates wether synchronization has been
achieved. If no synchronization has been
achieved, a red LED will be shown in this field.
Nominal Rate indicator
Shows the detected sample rate of the signal
Loudness Pilot is synced to.
Status section
Power indicator
Displays the current state of the Loudness Pilot
power supplies.
A power supply failure may be indicated as de-
scribed under “Power Warning parameter” on
page 46.
Power Warning parameter
A failing supply is always indicated by a red LED
on the front panel of the device. TC Icon can also
indicate a failing power supply, depending on the
setting of the “Power Warning” parameter.
“Off” setting
A failing power supply is not reported in the Icon
remote app.
“Warning” setting
A failing power supply is indicated by a yellow
“Power” label in the respective Loudness Pilot
Frame indicator, and a yellow LED will be shown
on the Frame tab when it is selected.
“Error” setting
A failing power supply is indicated by a red
“Power” label in the respective Loudness Pilot
Frame indicator, and a red LED will be shown on
the Frame tab when it is selected.