Loudness Pilotstatus indicators and ports
Loudness Pilot English Manual (2014-10-07) 27
Resetting Ethernet communication
It may be necessary to reset Ethernet communi-
cation between Loudness Pilot and a computer
during operation. To do so, proceed as follows:
During operation, insert a straightened paper
clip or a similar object into the “Reset” hole
on the front panel until it touches the button
behind the panel, and press the button for
approximately 5 seconds until the LEDs start
blinking.
This will reset Ethernet communication with-
out interrupting audio streams.
Back panel connectors
Fig. 16.: Loudness Pilot back panel
connectors (SDI version)
PSU (2 x)
Loudness Pilot has two C13 type power inlet
sockets. The dual power inlets provide extended
operational security and stability. They accept
100 to 230 Volts AC at 50/60Hz.
If possible, connect these two power sockets to
two independent power sources to minimize the
risk of power loss.
Due to the redundant design, Loudness Pilot
will still be fully operational when one of the two
power supplies fails. However, to ensure maxi-
mum security and stability, you should address
the issue and investigate the cause of the error
indication at the first given opportunity.
In case of complete power loss, the device is
hardware-bypassed via relays, ensuring that no
signal loss occurs.