15.1 Timeline Regions
To allow certain sections of the track to be evaluated, instead of the full track, the Finalizer allows you to set up a region of the full track. There is one region covering
A and B mode. The SPECTRO LAB measurements will be calculated for the selected region only. This way you may examine a specic region spectrally and dynamically
very closely and that may be complementing the two real time RTS meters (peak and RMS) very well.
Click and drag in the upper timeline view, and the Region window will appear.
• The lower timeline will change its horizontal scale to match the start and stop time of the new region. This enables better viewing of the waveform.
• The region’s start and stop times can be adjusted either by moving its left and right edges, or by moving the left and right markers in the lower waveform for
ner tuning.
• The complete region can also be moved by dragging the region’s top horizontal bar left or right.
• Regions for REF les can be set separately from the A/B-region, and dierent REF les can have dierent regions.
• To quickly switch from the region back to the full track time, click anywhere in the upper timeline waveform that is outside of the region. Click on the region top
bar to return to the region.
• Note that a region cannot be shorter than 1 second.
Tip:
• The precision in setting a region may be easier using the waveform view, rather than the loudness view.
• Observe how the SPECTRO LAB curves change as you focus on dierent time regions of the track.
15.2 Export Region
There is a separate Region for setting start and stop times when exporting the mastered track. This region can be set as follows:
• Click on the Export Module at the bottom of the Modules List View.
• The waveform or Loudness timeline will be shown as before, with the upper display showing the “Export Region.”