SNMP Documentation

Event Type
Level Description Signal Status <X> MIB value Notes
adevPresence(7) = lost(5)
adevFuzzyStatus(4) = error(2)
adevStatus(3) = fatal(5)
adevFuzzyStatus(4) = warning(1)
adevStatus(3) = warning(3)
adevPeaking(10) != 0
adevFuzzyStatus(4) = warning(1)
adevStatus(3) = warning(3)
adevDigInAnomaly(9) != 0
adevFuzzyStatus(4) = error(2)
adevStatus(3) = error(4)
adevDCInputs(12) != 0
adevFuzzyStatus(4) = error(2)
adevStatus(3) = error(4)
adevSilence(11) != 0
adevStatus(3) = warning(3)
adevDigInOverallStatus(8) = nolock(3)
adevFuzzyStatus(4) = error(2)
adevStatus(3) = error(4)
adevDigInOverallStatus(8) = slip(2)
adevFuzzyStatus(4) = warning(1)
adevStatus(3) = warning(3)
adevPresence(7) = lost(5)
adevFuzzyStatus(4) = error(2)
adevStatus(3) = fatal(5)
adevPrgChange(16) = Sequence number
adevPrgSummary(17) = Display string
adevPrgLoudnessOverCnt(18)
= number
adevPrgLoudnessOver(19) = Display string
adevPowerStatus(20)
= warning(2) / error(3)
adevFuzzyStatus(4)
= warning(1) / error(2)
In the table below the <X> column refers to one or more fields in aDevEntry, which contains information about the event/error type in the table row.
This means that for a device with a given device number (<DevNo>), the corresponding entry in thg MIB will be
.iso.ort.dod.internet.private.enterprises.tcelectronic.tcaprx1.tcadev.adevTable.adevEntry.<X>.<DevNo> , which in decimal form is .1.3.6.1.4.1.18203.1.3.1.1.<X>.<DevNo>
Status abbreviations: F: Fully Implemented. P: Partly Implemented. N: Not Implemented. NS: Not Implemented, but SNMP signaling is available.
TC SNMP Implementation Chart - DB6
Version 7.00
Icon version 7.00+ required
Icon version 7.00+ required
Icon version 7.00+ required
Digital Lock Error
No lock on selected digital input. Inspection required.
SNMP
Also reported via trap as "Lost connection"
Icon version 7.00+ required
Icon version 7.00+ required
Icon version 7.00+ required
Hardware Anomaly
Fatal
AC power failure. Fatal intenal failure. Immediate action required (Auto-change).
Hardware
/SNMP
Program Summary
Info
Summery of loudness measurements from previous program
SNMP
Program Summary
Info
Reset LM6, start data collection for new program summary. When incremented this will
generate a "Program Summary" trap containing the contents of adevPrgSummary(17)
SNMP
Warning
Number of Loudness Overs since last reset/program change. When incremented this
will generate a "Loundess Over" trap containing the contents of
adevPrgLoudnessOver(19)
SNMP
Loudness Over
Warning
Loudness Over alert
SNMP
Power Status
Warning
SNMP
AES slip (asynch) relative to reference clock at any input. Inspection required.
SNMP
Error
Silence Detect
Error
AES Slip Error
Warning
SNMP
Set if Clip on any input.(Threshold -0.5 dBFS)
Error
Warning
No Reply
Loudness Over
Warning/Error
SNMP
SNMP
SNMP
One of the power suplies without power
Fatal
Machine not reponding. Regarded as hardware anomaly. Immediate action required.
SNMP
Set if more than 5 sec continuous no signal on all ditigal inputs. (Threshold -70dBFs).
Output Clip
Input Clip
Input Anomaly 1
Input Anomaly 2
Warning
Clip on any output.
More than 3 sec contiunous over 1VDC (-18dBFs) at any input. Inspection required.
AES data error at input. (Validity, parity, non-pro). Abnormal signal to machine.
Inspection required.
SNMP

Summary of content (1 pages)