Manual
6 7
Quick Guide
Requirements
OneDB2LoudnessConsistencyProcessorand
a computer with an Intel Pentium (or better)
processor and Windows 95, 98, NT, 2000, ME
or XP installed.
Installation of TC Icon Editor Software
Enter the CD, open it, run Setup.exe and follow
the instructions shown on-screen.
Connecting DB2
• ConnecttheRS232InportoftheDB2toa
COM port on your PC. If there are several
COM ports, note to which port you have
connectedtheDB2.
(ThesuppliedRS232-to-USBconnectorcan
beusedtoconnecttheDB2toacomputer’s
USBport.However,notethatwhereRS232
can carry signal over cable lengths of up to
200meters,USBcablelengthsshouldnot
exceed 10 meters.)
• ProgrammingtheDB2doesnotnecessarily
require audio to be connected. However, if
audio connections are needed, make audio
connections according to the setup illustra-
tions in this manual.
Getting started with the TC Icon Editor
• PoweruptheDB2andstarttheTCIcon
software on your computer.
• GototheSetup/Devices/Portpageto
select which COM (1 to 4) port you have
connectedtheDB2(perdefault,theEditor
will look at COM ports 1 to 4 automatically).
• GototheSetup/Devices/Selectpage.
ClickDETECTandassignthedetectedDB2
to one of the eight device locations in the
right side of the display. To do so, simply
click any of the eight buttons.
• ClicktheICONbuttonintheupperleftcorner
togothepagesfromwherealllocalDB2
parameters are controlled.
Library Page: handles presets
System Page: handles Clock, Level trims,
Lock functions and the variable yellow LED
Threshold.
Engine: All algorithm parameters.
Cloning DB2’s using a PCMCIA card
OnceasingleDB2hasbeensetupforthe
desiredapplications,otherDB2’sinthehouse
can be easily cloned using a standard PCMCIA
card. In other words; it is NOT necessary to
hookupeverysingleDB2toacomputertoset
these up.
• InsertanunprotectedPCMCIAcardintothe
sourceDB2’scardslot.
• GototheTCIconSystem/Cardpage.
• Decidewhetheryouwishtoexcludethe
System Preset that hold overall Clock
settings, Analog Trim levels, Dither, Status
BitsettingsandGPIsettings.Toexcludethe
System Preset, activate the “Exclude System
Preset” button.
Then click CREATE CLONE CARD.
ALL DATA previously stored on the card
will be destroyed when formatting the
card! If the card is write-protected, no
data can be written on the card. The
protect/unprotect switch is located at the
edge of the card.
• RemovethecardandgotothetargetDB2
unit.
• PoweroffthetargetDB2unit.
• Insertthecardandpowerupusingthefront
panel POWER key while holding the OK key
pressed. Press UTILITY until the display
shows “C” (CLONE).
• NowpresstheOKkey.Allsettings(withor
without “System Preset”, depending on your
previous selection) are now copied to the
targetDB2.
QUICK START GUIDE
About this manual
The latest manual revision can always be downloaded from www.tcelectronic.com
If you have questions that are not answered by this manual, you may want to use our TC Support
Interactive site. This site is also accessed via www.tcelectronic.com
INTRODUCTION
The Tools
DB-2offersbroadcastersawidevarietyofconnectionoptionstoensuresimpleyetcomprehensive
integrationintoallofthemostpopularbroadcastingsystems.DB-2canalsobecontrolledremotely
with TC’s award-winning Icon software, allowing direct parameter control and preset switching from
any location.
Basedonanimmenselypowerful,lowlatencytopology,DB2offersahostof48bitresolutiontools
to be invoked simultaneously:
* LoudnesscorrectionasperITU-RBS.1770-2
* 5-band Level Optimization
* Online Delay Adjustment
* Adaptive Limiting
* Emphasis Compensation
* Filtering and EQ
* Stereo Width Adjustment
The Connections
AudioI/Oinclude24bitAES3-idonBNCconnectorsandbalancedanalogonXLRconnectorswith
analog domain gain scaling. Digital as well as analog inputs and outputs feature hardware bypass.
RemotecontrolmaybeestablishedviaRS232,USBand/orGPI,andSNMPsignalingisavailable
via the Icon application.