Owner's manual

REPLACEMENT PARTS
Order replacement parts from Taylor-Wharton, Cryogenic Equipment Plant, Theodore, Alabama or
the prime manufacturer. All replacement parts must be cleaned for oxygen service before
installation on the tank. If ordering from the prime manufacturer, provide the Taylor-Wharton part
number and all identifying information with part being serviced. Refer to tank Flow Diagram.
VACUUM-JACKETED CO
2
TANKS
Valve Number Description Part
Number
VJ-6 VJ-14 VJ-26 VJ-35 VJ-50
V-1 Ball Valve 2.0" FPT 85450371 - x x x x
V-1 Ball Valve 2.0" FPT 85450367 x - - - -
V-2 Ball Valve 1-1/2" FPT 85440366 x x x x x
V-3 Vacuum Gauge Valve 612921 x x x x x
V-4 Valve, Vacuum, 1.5” MPT 8545-0151 x x x x x
V-5,V-6 Ball Valve, 1/2" FPT 85450369 x - - - -
V-5, V-6, V-7 Globe Valve, 1/4” MPT 85443725 V-7 x x x x
V-8 Ball Valve, 1/4" MPT 85450368 x x x x x
V-9A, -9B Ball Valve, 1/2” FPT 85450369 x x x x x
V-10 Diverter Valve 1" 85449389 x x x x x
PCV Back Pressure Valve 1/4" Set at 325 psi 8536-8055 x x x x x
SV-1A,SV-1B Safety Relief Valve 3/4" Male Inlet x 1.0"
Female Outlet 350 psig
8545-1060 x x x x x
R-1 Casing Relief Device 2200763 x x x x x
PI Pressure Gauge 4-1/2" 0-600 psig 5714-3505 x x x x x
LI Barton Transmitter Differential Gauge
Lbs. of CO2
2208976 x - - - -
Barton Transmitter Differential Gauge
Lbs. of CO2
2205856 - x - - -
Barton Transmitter Differential Gauge
Lbs. of CO2
2205857 - - x - -
Barton Transmitter Differential Gauge
Lbs. of CO2
2205858 - - - x -
Barton Transmitter Differential Gauge
Lbs. of CO2
2205859 - - - - x
Flow Diagram 2208910 x - - - -
Flow Diagram 2210862 - x x - -
Flow Diagram 2210208 - - - x -
Flow Diagram 2210887 - - - - x
Operating Manual for the TW-VJ Series CO2 Tanks BT-235B
22