TOBY-L3 series - System Integration Manual
TSD-19090601 - R13 System Integration Manual Page 32 of 143
ACTIVE MODE
2G case: 0.44-2.09 s
3G case: 0.61-5.09 s
LTE case: 0.32-2.56 s
Paging period
Time
[s]
Current [mA]
Time
[ms]
Current [mA]
RX
Enabled
0
100
200
0
100
200
Figure 10: VCC current consumption profile with low power mode disabled and module registered with the network: active
mode is always held and the receiver is periodically activated to monitor the paging channel for paging block reception
1.5.2 Generic digital interfaces supply output (V_INT)
The V_INT output pin of the TOBY-L3 series modules is connected to an internal 1.8 V supply. This supply
is internally generated by a switching step-down regulator integrated in the Power Management Unit and
it is internally used to source the generic digital I/O interfaces of the cellular module, as shown in Figure
11. The output of this regulator is enabled when the module is switched on and it is disabled when the
module is switched off.
Baseband
Processor
70
VCC
71
VCC
72
VCC
5
V_INT
Switching
Step-Down
Power
Management
TOBY-L3 series
Digital I/O
Figure 11: TOBY-L3 series generic digital interfaces supply output (V_INT) simplified block diagram