User's Guide
Tarvos User Guide - Version 0.3 61
reader.flash_led()
Permission
admin
Min parameters
0
Max parameters
0
Flashes the reader LEDs for a few seconds to aid in reader locationing.
reader.is_alive()
Permission
guest
Min parameters
0
Max parameters
0
Pings the reader to ensure its operational.
reader.login()
Permission
guest
Min parameters
2
Max parameters
2
Performs reader login on current C2 cmd channel.
Param 1: 'login' ==> (Enum) User to login ('guest', 'admin', 'support')
Param 2: 'pwd' ==> (String) User password
Default password for 'admin' is 'admin' and for 'guest', its 'guest'.
Example:
reader.login(login=admin, pwd=admin)
ok
reader.logout()
Permission
guest
Min parameters
0
Max parameters
0
Performs reader logout on current C2 cmd channel. Login goes back to
setup.default_login_level.
reader.who_am_i()
Permission
guest
Min parameters
0
Max parameters
0
Reports the current login level ('guest', 'admin', 'support')