User's Guide
Tarvos User Guide - Version 0.3 56
modem.protocol.isob.filter.f.data
Read Permission
admin
Write Permission
admin
Default
0x00000000000000
00
Priority
5
(Hex Array) Data for the ISOB group select filter (exactly 8 bytes).
The value in this field will be compared with the value on the
tag (if the corresponding bit in the Byte mask is set) for
the group select.
modem.protocol.isob.filter.f.opcode
Read Permission
admin
Write Permission
admin
Default
SELECT_EQ
Priority
5
(Enum) The group select command to use for this filter.
Possible values: SELECT_EQ, SELECT_NE, SELECT_GT, SELECT_LT,
UNSELECT_EQ, UNSELECT_NE, UNSELECT_GT, UNSELECT_LT,
modem.protocol.isoc.physical.pilot_tone
Read Permission
admin
Write Permission
admin
Default
false
Priority
5
(Boolean) If 'false', the use of the pilot_tone(TREXT) will be automatically
determined by the reader. If 'true', the pilot tone will be always be
used for a higher sensitivity reader.
modem.protocol.isoc.control.user_data_offset
Read Permission
admin
Write Permission
admin
Default
0
Priority
5
(Integer) User data offset for tag reports or tag.read_user_data.
modem.protocol.isoc.control.user_data_length
Read Permission
admin
Write Permission
admin
Default
0
Priority
5
(Integer) User data length for tag reports or tag.read_user_data.