User's Guide
Tarvos User Guide - Version 0.3 40
diag.error_status
Read Permission
admin
Write Permission
none
Default
NULL
Priority
-1
(Enum) Displays error status
Possible values are 'critical', 'error', 'warning', or 'none'
Check reader.view_logs() to obtain additional information if 'none' is not
returned.
diag.radio_error_status
Read Permission
admin
Write Permission
none
Default
NULL
Priority
-1
(Enum) Displays radio error status
Possible values are: 'none', 'VSWR shutdown', 'Temp shutdown',
'Internal Port shutdown', 'Error shutdown'
'Regulatory shutdown'
Check reader.view_logs() to obtain additional information if 'none' is not
returned.
diag.log_llrp
Read Permission
admin
Write Permission
admin
Default
NULL
Priority
-1
(Boolean) Log upstream LLRP cmd/resp packets (Do NOT set this without help from
tech support).
diag.print_to_serial
Read Permission
admin
Write Permission
admin
Default
NULL
Priority
-1
(Boolean) Prints syslog and diagnostic information on the RS232 port
(default is off).
diag.cpu_temp
Read Permission
admin
Write Permission
none
Default
NULL
Priority
-1
(double) Displays the CPU internal temperature.