com.network.ntp_sync_period
Read Permission
admin
Write Permission
admin
Default
NULL
Priority
-1
(Integer) Set the NTP sync period in seconds.
Minimum valus is 10 and maximum is 120.
Example:
com.network.last_ntp_error
ok 1230
com.serial.baudrate
Read Permission
guest
Write Permission
none
Default
NULL
Priority
-1
(Enum) Baudrate for serial communication.
Read only. Set with com.serial.set().
Possible values: '1200', '2400', '4800', '9600', '19200', '38400', '57600',
'115200'
com.serial.databits
Read Permission
guest
Write Permission
none
Default
NULL
Priority
-1
(Enum) Databits for serial communication.
Read only. Set with com.serial.set().
Possible values: '7', '8'
com.serial.echo
Read Permission
guest
Write Permission
none
Default
NULL
Priority
-1
(Boolean) Echo for serial communication.
Read only. Always 'false'. Serial communications does not support
echo.
com.serial.parity
Read Permission
guest
Write Permission
none
Default
NULL
Priority
-1
(Enum) Parity for serial communication.
Read only. Set with com.serial.set().
Possible values: 'none', 'even', 'odd'