User's Guide
Tarvos User Guide - Version 0.3 72
h. Setup
Variable List Table
setup.advanced.hop_early
setup.advanced.do_opspecs_once
setup.operating_mode
setup.advanced.preferred_frequencies
setup.advanced.valid_frequencies
setup.sub_region
setup.region
setup.valid_regions
setup.protocols
setup.install_type
setup.default_login_level
setup.event_notifications
setup.tag_volume
setup.valid_protocols
setup.heartbeat.ip_address
setup.heartbeat.port
setup.heartbeat.interval
setup.advanced.hop_early
Read Permission
admin
Write Permission
admin
Default
0
Priority
0
(Integer) Setting this value to 1 in fixed frequency regulatory regions that
allow multiple 'setup.advanced.preferred_frequencies', will enable the
reader to always try and transmit on the first specified frequency when
it can. So, if the regulatory region requires a minimum off time of 100
ms, the reader will only be off the first channel for 100 ms and it
will then hop early back to the first channel.
If this value is set to 0, the reader will hop through all the
frequencies in the 'setup.advanced.preferred_frequencies' list one
at a time as required by the regulatory region.
setup.advanced.do_opspecs_once
Read Permission
admin
Write Permission
admin
Default
true
Priority
5
(Integer) Determines if we continue to perform tag operations repeatedly while
its "in the field". If this value is true, after a tag arrives,
each user data read, or tid read, or tag security operation happens
once. A value of true will provide better performance if a tag only
needs to have operations performed upon it once.
A value of false will force each tag operations to be performed every
time that tag is singulated. A tag is "in the field" from the time
it arrives and before it departs. After a tag departs, it is no longer
considered "in the field" and future arrivals will cause the operation
to occur again.