User's Guide
Tarvos User Guide - Version 0.3 41
diag.sockets_info
Read Permission
none
Write Permission
none
Default
NULL
Priority
-1
(String) Displays socket info.
max total blocks (sockets), max used at any time, current total sockets,
current sockets available.
diag.error_handler.period
Read Permission
admin
Write Permission
admin
Default
60
Priority
-2
This variable is ignored. Only a placeholder for backward compatibility
diag.temp_check_period
Read Permission
admin
Write Permission
admin
Default
0
Priority
5
(Integer) If greater than 0, reader will log the temperature every
diag.temp_check_period
minutes. The log will appear in the DEBUG logs.
d. DIO
Variable List Table
dio.in.debounce
dio.num_inputs
dio.num_outputs
dio.in.d
dio.out.d
dio.trigger_high.d
dio.trigger_low.d
dio.in.debounce
Read Permission
admin
Write Permission
admin
Default
1000
Priority
5
(Integer) DIO debounce time in microseconds
dio.num_inputs
Read Permission
admin
Write Permission
none
Default
NULL
Priority
-1
(Integer) Number of dio input pins on the reader.