Installation Instructions

ID_20201110_EN_FIBERFLOOR
Page 6 of 6
© 2020 Tarkett USA Inc. 11/2020
ADHESIVE CLEAN UP
QBond One Adhesive
Use a clean white cloth dampened with water to remove wet adhesive from floor covering and tools.
Dried adhesive may require the use of mineral spirits applied to a clean white cloth (Follow manufacturer’s precautions when using
mineral spirits).
FINISHING THE JOB
1. Carefully inspect for any fullness in the flooring. Re-trim if necessary. Flooring shall be lying flat. It is recommended that all exposed edges be
covered. Install wood moldings or cove base around the perimeter to cover the space. Do not fasten or nail moldings through FiberFloor. Fasten
into the wall.
2. Use transition moldings at doorways or where the new flooring meets an existing floor. Do not nail or fasten the molding through the flooring.
Transition moldings shall be fastened to the substrate. If a transition molding must be installed directly on top of flooring, mark on the flooring
where each fastener will be positioned, and drill or cut a hole larger than the size of the fastener. This is necessary when using the Floating
Installation Method.
3. Do not move or roll furniture and appliances directly over floor. Always place plywood or hardboard panels on floor when moving furniture or
appliances.
4. Furniture legs shall be equipped with proper size rests to prevent permanent indentations.
CARE AND MAINTENANCE
Check furniture to be sure the legs are equipped with proper rests and are of sufficient size with a minimum bearing surface of 1” square (or 1
1/8 diameter per 50-75lbs.) to prevent permanent indentations. Polished metal or non-staining, smooth plastic are recommended. Do not use
felt pads.
Use extreme caution when moving heavy furniture or appliance across the flooring. The use of plywood or hardwood panels to slide the
furniture or appliances is recommended.
Narrow-heeled shoes can damage the flooring causing permanent indentation that is not covered by the warranty.
Light daily sweeping or vacuuming will help maintain the floors original gloss by removing any grit particles, which can affect the normal gloss.
Sweep and / or vacuum (without a beater bar) any dirt or debris that can abrade or scratch the floor. Use a soft brush, dust mop, or vacuum with
the beater bar turned off.
Wipe up spills promptly and thoroughly with a clean, damp cloth. Spills are easier to remove if wiped up immediately.
When necessary, wash the floor with a neutral pH floor cleaner such as ammonia diluted in water.
Use non-staining walk-off mats at outside entrances to prevent dirt and debris from being tracked onto the floor. Discoloration of the flooring
may occur from rubber backings and dyes used in floor mats and rugs. Consult the rug manufacturer to ensure their products are compatible
with vinyl flooring.
As with other household furnishings, repeated exposure to direct sunlight may cause bleaching, fading or discoloration. When possible, close
drapes or blinds during peak sunlight hours to block direct sunlight.
INSTALLATION IN CABINS AND VACATION HOMES
NOTE: FiberFloor can be installed in fully-enclosed buildings like vacation homes and cabins that may have HVAC controls turned off periodically.
Adhere directly to the substrate using the Full-Spread-Permanent Application method detailed above. On-grade or above grade concrete substrates
meeting the requirements detailed in the CONCRETE SUBSTRATES section and double layer wood constructed substrates detailed in the WOOD
SUBSTRATES section are recommended for this application. Contact Tarkett Technical Services at (800)-899-8916 with any questions.
Special Instructions
Acclimate the flooring materials and adhesive in an indoor, climate controlled space to between 65°F and 85°F (18.3°C and 29.4°C) for 48
hours prior to installation.
Maintain climate controls of between 65°F and 85°F (18.3°C and 29.4°C) with a relative humidity 40% and 60% for 48 hours prior to, during,
and after the installation.
Maintain a minimum substrate temperature of 60°F (15.6 ˚C) for 48 hours prior to, during, and after installation. Substrate temperature should
be a minimum of 5˚F higher than the dew point temperature
When traffic will be present, maintain climate controls of between 6F and 85°F (18.3°C and 29.4°C) with a relative humidity 40% and 60%.
Restrict traffic any time the HVAC has not been in operation to protect the flooring.
FiberFloor may only be installed in this application following the Full Spread Permanent Bond method.
Tarkett North America
Technical Services Department
30000 Aurora Road
Solon, OH 44139
800.899.8916 Fax 440.632.5643
info@tarkettna.com
www.tarkettna.com