Installation Instructions

ID_20201110_EN_FIBERFLOOR
Page 1 of 6
© 2020 Tarkett USA Inc. 11/2020
FIBERFLOOR® SHEET VINYL
INSTALLATION INSTRUCTINS
INTRODUCTION
These instructions are written as a guide to be used when installing Tarkett FiberFloor®. These instructions, combined with our adhesives and flooring
products, create a system. Utilizing this system will ease the installation process and provide the customer with a completed product that will perform to its
intended purpose. Always visit www.tarkettna.com for the most current installation and maintenance instructions. Technical videos and tip sheets are
also available. Contact Tarkett Technical Services at (800)-899-8916 with any questions.
GENERAL INFORMATION
1. Carefully check flooring material for any defects. Contact your supplier immediately if any defect is found.
2. Tarkett floors are intended for indoor use only.
3. FiberFloor can be installed in cabins or vacation homes that may not receive permanent HVAC climate control. See special instructions at the end
of this document to ensure a successful installation.
4. All Tarkett products, flooring and adhesive must be stored in an indoor climate controlled space and be protected from the elements. Temperature
must be maintained between 65°F and 85°F (18.3°C and 29.4°C) with a relative humidity 40% and 60%
5. FiberFloor must be acclimated at room temperature between 65°F and 85°F (18.3°C and 29.4°C) for 48 hours before, during and after the
installation.
6. Exposure to direct sunlight can result in products fading and creates excessive heat directly on the finished flooring and surrounding structure,
which may result in movement. During peak sunlight exposure, the use of drapes or other window treatments are recommended.
7. Rolls must be stored horizontally on smooth surface supporting the entire width of the roll at all times prior to the installation.
8. FiberFloor must be rolled on a sturdy core, design in or design out, when transporting to the jobsite.
9. Protect rolls from damage.
10. Remove all transitions, quarter round, baseboard molding or cove base prior to beginning the installation.
11. Tarkett ProSheet™ Plus 3 is an approved underlayment for use with FiberFloor in on or above grade applications. Do not use ProSheet Plus 3
below grade.
12. Tarkett recommends using Tarkett Q-Bond One™ or 959™ Vinyl Plank & Tile adhesive with installing this flooring product as a Full Spread
method. Issues associated with the use of non-recommended adhesives are excluded from Tarkett’s limited warranty. See complete Limited
Warranty for details.
WOOD SUBSTRATES
FiberFloor may be installed over single layer wood construction in res ident ial applic at ions only , when used with ProSheet Plus 3 underlayment.
Follow the detailed ProSheet Plus 3 installation instruction found a t www.tarkettna.com
Wood subfloors must meet the following requirements:
1. Wood joist or truss systems spacing must be a maximum of 16” on center when installing over single layer wood construction.
2. Wood joist or truss systems spacing of 16”-19.2 is acceptable for double layer wood construction.
3. Subfloor panels must be dry, sturdy, smooth, dimensionally stable and structurally sound.
4. Subfloor panels must be 3/4” minimum thickness tongue and groove plywood or oriented strand board (OSB).
5. Plywood subfloor panels must consist of a solid core (no voids).
6. Subfloor panels must be exterior grade or classified as Exposure I.
7. All suspended wood subfloors must have at least 18” of well-ventilated air space clearance above the ground. The ground under the crawlspace
shall be covered with 10 mil or thicker polyethylene sheeting to reduce moisture vapor transmission.
8. Offset subfloor panel joints by at least 16” so that four corners do not meet.
9. Subfloor panels must be securely fastened to the joists and free from spring or deflection. If glue-nail procedures are required, use solvent free
construction adhesives.
Wood subfloors not meeting the above requirements must be covered with 1/4” minimum thickness underlayment grade plywood. Follow all
APA and manufacturer’s guidelines for installing underlayment grade plywood.
Tarkett recommended underlayments include:
APA Underlayment Grade Plywood A-C, B-C, or C-C Plugged
ACCU-PLY
SurePly
TecPly
ULAY
C.S.A (CanPly) and Proboar

Summary of content (6 pages)