Technical Specifications
Read all instructions carefully before beginning installation. Make sure that the instructions are the most recent
version. Visit www.tarkettna.com for current instructions.
STORAGE AND HANDLING
• Pallets shall not be stacked more than four high.
• Cartons of laminate must be stored horizontally at all times.
• Storage area shall be climate-controlled with a minimum temperature of 65ºF. (18ºC.). Relative humidity shall be between
40% and 70%.
• Protect carton corners from damage.
• Do not damage or remove plastic wrapping.
TOOLS AND MATERIALS
Vacuum Undercut Saw 10 mil polyethylene (concrete only)
Safety Glasses Table Saw Tarkett foam underlayment
5/16” (8.2mm) Spacers Miter Saw
T-square Jig Saw
Tape Measure Circular Saw
Hammer Plastic Packaging Tape
Tapping Block Dust Mask
Pull Bar PVA laminate glue
WARNING: EXERCISE EXTREME CAUTION WHEN OPERATING POWER TOOLS. OPERATIONS INVOLVING SAWING,
SANDING OR MACHINING OF WOOD PRODUCTS CAN PRODUCE WOOD DUST. AIRBORN WOOD DUSTS CAN BE AN
EXPLOSIVE HAZARD. WOOD DUSTS MAY ALSO CAUSE RESPIRATORY, EYE AND SKIN IRRITATION. THE
INTERNATIONAL AGENCY FOR RESEARCH ON CANCER (IARC) HAS CLASSIFIED WOOD DUST AS A NASAL
CARCINOGEN IN HUMANS. POWER TOOLS MUST BE EQUIPPED WITH A DUST COLLECTOR.
SUBSTRATE REQUIREMENTS
Tarkett Laminate Flooring may be installed over most types of substrates and existing floors on all grade levels.
• All substrates must be structurally sound and free from movement or deflection.
• The substrate must be clean, dry, level and free of any defects.
• The substrate must be level within 1/4” in 8 ft. (6.3mm in 2.4m).
• Smooth and level all irregularities with a cementitious patching and leveling compound.
Concrete
• Concrete substrates shall be properly cured and allowed to dry for at minimum of 90 days before installation.
• Moisture vapor transmission shall not exceed 3 lbs./ 1000 sq.ft./24 hours per ASTM F 1869 Calcium Chloride Test.
• Internal relative humidity of concrete shall not exceed 75% when tested according to ASTM F 2170.
Wood
• Suspended wood substrates shall have a minimum 18” (45cm) of well-ventilated air space (crawl space) clearance above
the ground.
• A moisture vapor retarder shall be installed over the ground with overlapped widths and lengths. Moisture content of wood
substrate shall not exceed 12%.
Existing Sheet and Tile Flooring
• Existing flooring must be fully adhered and in good condition.
• Repair any damaged areas.
TECHNICAL
SERVICE
Laminate Flooring
T-Lock Angle-Tap
Installation Instructions
October 26, 2011