User's Manual

GV300TP User Manual
TRACGV300TPUM001 - 16 -
Table 9.Electrical Characteristics of the Digital Inputs
Logical status
Electrical characteristics
Active
0V to 0.8V
Inactive
Open
The following diagram shows the recommended connection of a digital input.
Figure 9.Typical Digital Input Connection
3.9.Analog Inputs
There are two analog inputs on GV300TP, and the analog input voltage range is from 0 to 32V.
The following diagram shows the recommended connection.
Figure 10.Typical Analog Input Connection
Note:
PIN 12 and PIN13 are multifunction pins: it can be configured as a digital input or an analog
input.
PIN 15 is a multifunction pin: it can be configured as a digital input or a negative output.