Technical Specifications
Rev 8/2019 © 2019 Tarco All Rights Reserved. Printed in U.S.A.
Application
Cut the EasyStick Plus roll to suitable, manageable
lengths before installation.
Position the pre-cut EasyStick Plus beginning at the
lowest corner of the roof where the eave (gutter edge)
and rake (rising edge) intersect.
Align EasyStick Plus so that it is parallel with the edge of
the eave and extend over the eave and rake approx. 3/8”.
Starting at the middle and extending to one end of
EasyStick Plus, drive securing nails in 18" centers in the
side lap area, 1½" from the edge. Do not drive the nails
all the way in.
Backroll the unsecured portion of the roll up the middle
where the first securing nail is driven.
Apply a 1/16" thick layer of asphalt plastic cement over
the eave and rake metal drip edges extending 2" to 3"
onto the deck surface where the roll will intersect.
Carefully remove the release film the full width of the
sheet and apply the EasyStick Plus membrane firmly into
place as it is being applied, taking care to avoid wrinkling
or creasing of the roll.
Remove the securing nails from the other half of
EasyStick Plus, backroll and apply in like manner.
On slopes greater than 2:12, drive nails flush in the
Warranty
sufficient ventilation, including both ridge and soffit
venting.
A full, irreversible adhesion is achieved when the
membrane goes through a complete heat cycle. Do not
Tarco Specialty Products, Inc. offers 10, 15, 20 and 25 Year Limited Warranties.
Surface Preparation
Surface must be clean, dry, and without voids that may
interfere with adhesion.
For re-roofing, all old roofing and other loose materials
must be removed prior to installation.
When adhering to EasyBase
TM
self-adhering base sheet,
remove any loose film from the EasyBase surface.
If the EasyBase self-adhering base sheet has been left
exposed for more than 30 days, prime the EasyBase
NOTE: All statements, information and data, given herein are believed to be accurate and reliable but are presented without guaranty, warranty or responsibility of any
kind, expressed or implied, except as may be indicated otherwise in this literature. Statements or suggestions concerning possible use of our products are made
without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe any patent.
Tarco
One Information Way, Suite 225
Little Rock, AR 72202
Voice: 501-945-4506
800-365-4506
Fax: 501-945-7718
www.tarcoroofing.com
Properties
Property Typical Value Test Method
Max Load
@
0°F, MD & XMD 75 lbf/in ASTM D6164
Elongation
@
0°F, MD & XMD 20% ASTM D6164
Max Load
@
73.4°F, MD & XMD 55 lbf/in ASTM D6164
Elongation
@
73.4°F MD & XMD 35% ASTM D6164
Tear Strength
@
73.4°F 55 lbf ASTM D6164
Low Temperature Flexibility 0°F ASTM D6164
Product Data
Width 36 in
Length 36 ft
Weight 73 lb
(nominal)
Thickness 120 mil
(nominal)
Gross Coverage 108 sq ft
Property Typical Value Test Method
Dimensional Stability, max 1% ASTM D6164
Compound Stability @ 215°F Pass ASTM D6164
Granule Adhesion 1 g loss ASTM D4977
Adhesion to Plywood @ 40°F 4 lb/ft of width ASTM D1970
Adhesion to Plywood @ 75°F 25 lb/ft of width ASTM D1970
Thermal Stability, max 0.1 in ASTM D1970
attempt to remove the membrane immediately after
adhesion to the substrate.
Use of a hand-held “hot air gun” might help enhance
adhesion during application of membrane in cooler weather.
surface prior to installation of the EasyStick Plus
membrane.
Acceptable substrates for adhesion of LeakBarrier
membranes can be found at the Tarco website.
For best results, EasyBase surface may be primed with an
ASTM D 41 Primer prior to installation of EasyStick Plus.
When primer is used, ensure the primer is fully dry prior to
application of EasyStick Plus.
selvage area 1½" from the edge on 18" centers, after
EasyStick Plus has been applied and prior to the next
overlapping course.
Apply the next eave course in the same manner
overlapping the first course at the end lap by 6".
Apply a uniform 1/16" thick layer of asphalt plastic
cement the full roll width to the surface of the first course
in the 6" end lap area before adhering the next course.
Remove release film covering the selvage, if present,
prior to application of the sheet.
Lap the succeeding course over the side lap area just to
the granular edge of the preceding course.
Apply succeeding courses in like manner, as in steps
above.
Stagger the end laps a minimum 3' from the preceding
course.
At the T-joint (where an end lap and next overlapping
course intersect), apply a bead of roofing lap cement
before the overlapping course is laid.
Roll the entire membrane surface, paying special attention
to side laps, end laps and T-joints. Roller weight shall be
70 lb. minimum for low slope (<2:12 pitch) and 28 lb.
minimum for steep slope (>2:12 pitch).