3.1.2 Network Settings
This section describes the parameters which define the TUNet network the device will operate on.
Figure 19: TUNet Programmer Network Settings
The following table describes the settings taken from the screen shot above.
3.1.3 Application Settings
This section describes the settings for the automated meter reading and power quality monitoring applications supported by
the Tantalus Utility Network (TUNetâ„¢).
Figure 20: TUNet Programmer Application Settings
The following table describes the settings taken from the screen snapshot above.
Enable consumption
reporting
Check this option to enable the TUNet module to report consumption on regular intervals. If
consumption reporting is enabled, a reporting interval must be entered. Valid values are 1 to 127
minutes. The default value is 15 minutes.
Enable power quality
reporting
Check this option to enable the TUNet module to report power quality on a regular basis. If
power quality reporting is enabled, a reporting interval must be entered. Valid values are 1 to 24
hours. The default value is 6 hours.
Enable power outage
reporting
Check this option to enable the TUNet module to report power outages. If power outage
reporting is enabled, a minimum sustained outage period must be entered. Valid values are 1 to
10 seconds. The default value is 10 seconds.
Utility business identifier Enter the Tantalus assigned business identifier for the utility company network. If more than
one utility company is using the same TUNet, each company must have their own unique
business identifier. Valid values are 21 to 16382. The default value is 102.